IP 65 PROTECTION
The equipment is designed and tested for IP65 protection in accordance with EN 60529.
This degree of protection corresponds to resistance to dust and water (jets of water)
allowing the product to be used outdoors. However, it does not protect against immersion.
For ports with protective caps: Handle the protective caps on the connectors with care, as they en-
sure that the product is dust- and water-tight. When the port is not in use, check that the connec-
tors are free of dust and moisture, and close the protective caps carefully.
The IP65 rating does not guarantee the device's resistance to outdoor conditions (UV, heat,
temperature variations...).
Warning! the AC adapter is not protected against water and humidity. Do not connect this device to
the mains when outdoors. Only battery power is available for IP65 use.
PRODUCT INSTALLATION
POWER SUPPLY
Power adapter included.
Power IN
100-240V~
Power OUT
12,6V⎓ 1A
DMX CONNECTION
Connection between lights and DMX must use the shied cable of diameter more than 0.5mm. Please use the
attached 3 pin XL plug/socket to connect the DMX output/input interface. The connection between socket and
cable as below (note the plug/socket's 3 pin number and position).
DMX-OUTPUT
XLR mounting-sockets (rear view)
2
3
When using standard DMX512 control signal, the last device' s output interface must be connected to a DMX plug. This
plug is putting a 120 ohm resistance between "canon" plug' s 2 pin and 3 pin. Showing as below pic. Sticking this plug
into the last device' s signal output interface, it will avoid the interference during the process of signal transmission.
RIGGING
Attention! The installation must be carried out by qualified service personal only. Improper installation can re-
sult in serious injuries and /or damage to property. Overhead rigging required extensive experience! Working
load limits should be respected, Certified installation materials should be used, the installed device should be
inspected regularly for safety. The device can also be mounted on a magnet structure, using the magnet sup-
plied in the EVENTPART44 QUAD IP accessory pack. EVENTPART44 QUAD IP accessory pack (not included)
containing a case, a magnet, a Frost screen and an integrated power supply.
XLR mounting-plugs (rear view)
1 ∙ Shield
2 ∙ Shield (-)
1
3 ∙ Shield (+)
DMX-INTPUT
2
1
3
P.19
PIN3
PIN2