Material
The maximum pressure
supported
Connection
Supply voltage
Valve closing time in case
of alarm
Dimensions
Operating temperature
Installation instructions
•
First identify if the gas from the source is heavier or
lighter than air. Gases heavier than air: LPG, etc. Gases
lighter than air: natural gas, methane gas, etc.
•
Depending on the weight of the gas, choose the correct
location of the gas detector.
•
If the gas is heavier than the air, position the gas
detector at a height of 0.3 - 1.0 m from the floor, within
a radius of max. 1.5 m from the gas source. If the gas is
lighter than the air, position the gas detector at a height
of 0.3 - 1.0 m from the ceiling, within a radius of max.
1.5 m from the gas source.
Aluminum alloy
100 kPa
ø
3/4"
DC 9 ~ 12 V (electrical
impulse)
< 1 sec.
75 x 45 x 110 mm
-26°C ~ +80°C
5