Material
The maximum pressure
supported
Connection
Supply voltage
Valve closing time in case
of alarm
Dimensions
Operating temperature
Installation instructions
First identify if the gas from the source is heavier or
lighter than air. Gases heavier than air: LPG, etc. Gases
lighter than air: natural gas, methane gas, etc.
Depending on the weight of the gas, choose the correct
location of the gas detector.
If the gas is heavier than the air, position the gas
detector at a height of 0.3 - 1.0 m from the floor, within
a radius of max. 1.5 m from the gas source. If the gas is
lighter than the air, position the gas detector at a height
of 0.3 - 1.0 m from the ceiling, within a radius of max.
1.5 m from the gas source.
Aluminum alloy
100 kPa
ø
3/4"
DC 9 ~ 12 V (electrical
impulse)
< 1 sec.
75 x 45 x 110 mm
-26°C ~ +80°C
5