2. When selecting F1 from the main screen, the Pro50™ can
test and operate the remote DC latching valve solenoids. On
this DC screen, use the F1 ON to activate the solenoid or
use F2 CHATTER to make the solenoid quickly turn on and
off to locate (BE SURE THE WATER IS TURNED OFF).
Selecting F3 turns both F1 and F2 off.
3. Press the left arrow to return to the main screen. Press the
right arrow to go to the next screen, which is the multimeter
screen.
F3: Operation with AC controllers solenoids.
Again, from the main menu, for AC valve actuation or chatter, use
F3. This takes the user to the AC solenoid menu (see picture
below). Once on this menu, the instructions are the same as above
in the F1 section.
F2: Two-wire irrigation fault-finding mode
From the main menu, press F2 to access the two-wire irrigation fault
finding mode. This mode places power on field cables via the test
leads, allowing the user to troubleshoot the system using a milliamp
clamp meter (like the Armada Pro95i). The clamp meter can detect
4