Multiroom IP central amplifier
5. If there is no LAN network connected to the Ethernet socket, or there is
no router with DHCP and automatic IP, after 15 seconds the SYSTEM
STATUS led will start flashing rapidly. This is becausethe equipment,
by default, asks the router for an automatic IP address, and if there is
none, the led starts flashing rapidly.
If there is an Ethernet network and a router with DHCP, the ETHERNET
led will light up, and, on receiving an automatic IP address, the SYSTEM
STATUS led will light up with a steady light indicating that the equipment
has started up correctly.
If there is no LAN IP network, with the SYSTEM STATUS led flashing
rapidly, in order to continue checking the installation we will have to
make a short press on RESET on the front cover, and we will see that
after a second the SYSTEM STATUS led will briefly turn off and then
turn on again in green and fixed, starting the system with a fixed IP
address, such as 192.168.1.2.
6. After 2-3 seconds we will see all the output leds (OUT1 to OUT8) light
up orange for 1 second, and then they will turn off, leaving only the
POWER and SYSTEM STATUS leds permanently lit.
7. In this step the equipment will be correctly switched on to be able to
go on to the TEST tests.
To do this, by pressing the RESET button again briefly, the equipment
will switch to TEST mode and will progressively start to sound in each
output indicating in english and spanish Zone 1/Zone 1, ... , first in
output OUT 1, then in OUT 2, and so on up to OUT 8, starting again
with OUT 1 in an uninterrupted manner so that the installer can check
speaker by speaker, zone after zone, not only the correct operation of
the speakers but also the corresponding zones.
During this process, while the sound sounds in each output or zone,
the OUT X output led of the corresponding zone will light up, allowing
not only an acoustic check, but also a visual check on each led on the
front panel of the Multiroom IP equipment.
8. Once this process is finished, if we press the RESET button again, the
equipment will finish with it and will satart another TEST, playing DEMO
music in all the zones or OUT X outputs at the same time, together with
all the leds on in the zones, to acoustically check that all the loudspeakers
are working correctly.
C O N N E C T I O N T Y P E E X A M P L E
Configurable from 1 to 8 outputs,
and from 3 W, 6 W, 12 W, 25 W to 50 W
(Factory default: 8 zones, 6 W, mono)
Central or local intercom for call notification,
or for alarm centrals or other events
EGi's catalogue offers a wide range of loudspeakers and baffles for this system, for example:
HQ or HiFi ceiling loudspeakers
Electroacústica General Ibérica, S.A. • Av. Almozara, 79 • 50003 ZARAGOZA - Spain • T. +34 976 40 53 53 - +34 976 40 53 56 • F. +34 976 40 53 54 • e-mail: info@egiaudio.com • www.egiaudio.com
SERIE 42000
Multiroom IP
42002.0
(8 configurable audio outputs)
Room 3
(stereo)
Room 2
(mono)
Room 1
(mono)
N L
115 - 230 V~
Minuet HiFi baffles
06818
(If not all outputs are connected, no acoustic signal will be received in
these zones, but the led will indicate their operation).
9. If we press the RESET button again with another short press, the equipment
will indicate by voice the number of the IP address taken (in english and
spanish), either automatic DHCP or manual if we have pressed the RESET
button at the beginning. At the same time, all the output leds will light up.
(This application is particularly interesting for installations with fixed or
manual IP addresses).
10. Another short press on the RESET button will put the equipment in
standby mode, with only the POWER and SYSTEM STATUS leds lit, to
either test again or to switch it off from the mains and wait for an automatic
IP LAN DHCP network with router at a later date.
NOTE: If you are going to reconnect to a router with automatic IP address or
DHCP, we recommend that you turn it off the mains and do not turn it on
again until you have connected the router to the equipment.
e) RESET keystrokes summary (Fig. 2):
– 1st short press:
(in case of NOT starting with automatic DHCP) start the equipment in
fixed or manual IP mode 192.168.1.2.
(in case of YES automatic DHCP start-up) the equipment goes directly
to TEST mode.
– 2nd short press: the unit switches to TEST mode and Zona X/Zone X
sounds for each zone, in english and spanish.
– 3rd short press: the unit switches to TEST mode with an included DEMO
song playing in the speakers of all zones.
– 4th short press: the equipment continues in TEST mode, broadcasting
the current IP address through the loudspeakers in english and spanish.
– 5th and last short press: returns to normal standby mode (ON).
– Long press for more than 10 seconds: RESET to factory setting.
To use the complete device, connect it to an IP LAN network with DHCP, WiFi
and internet connection.
Room 4
Room 5
Room 6
WiFi
Doorbell
Ethernet IP network connection
Pendant baffles
In/Out rock baffles
06824-06826
(stereo)
(mono)
(mono)
DIN rail
1 USB WiFi/Bluetooth
connection for
®
wireless link (coming soon).
2 USB MUSIC 2.0 connection for music
via memory stick.
In/Out HiFi Projector
06808.04