Declaration of Incorporation of Partly Completed Machinery
in accordance with Schedule 2 Part 2 Annex II, section 1.B. of the Directive 2008 No. 1597
Supply of Machinery (Safety) Regulations 2008
For the following product:
Type 3510 Pneumatic Control Valve
We certify that the Type 3510 Pneumatic Control Valves are partly completed machinery as defined in the in
Directive 2008 No. 1597 Supply of Machinery (Safety) Regulations 2008 and that the safety requirements stip-
ulated in Annex I, 1.1.2, 1.1.3, 1.1.5, 1.3.2, 1.3.4 and 1.3.7 are observed. The relevant technical documentation
described in Annex VII, (Part 7 of Schedule 2) part B has been compiled.
Products we supply must not be put into service until the final machinery into which it is to be incorporated has
been declared in conformity with the provisions of the Directive 2008 No. 1597 Supply of Machinery (Safety)
Regulations 2008.
Operators are obliged to install the products observing the accepted industry codes and practices (good engi-
neering practice) as well as the mounting and operating instructions. Operators must take appropriate precau-
tions to prevent hazards that could be caused by the process medium and operating pressure in the valve as
well as by the signal pressure and moving parts.
The permissible limits of application and mounting instructions for the products are specified in the associated
mounting and operating instructions; the documents are available in electronic form on the Internet at
www.samsongroup.com.
For product descriptions refer to:
-
Type 3510 Valve (DIN): Mounting and Operating Instructions EB 8091
-
Type 3510 Valve (ANSI): Mounting and Operating Instructions EB 8091-1
Referenced technical standards and/or specifications:
-
VCI, VDMA, VGB: "Leitfaden Maschinenrichtlinie (2006/42/EG) – Bedeutung für Armaturen, Mai 2018"
[German only]
-
VCI, VDMA, VGB: "Zusatzdokument zum Leitfaden Maschinenrichtlinie (2006/42/EG) – Bedeutung für
Armaturen vom Mai 2018" [German only], based on DIN EN ISO 12100:2011-03
Comments:
-
See mounting and operating instructions for residual hazards.
-
Also observe the referenced documents listed in the mounting and operating instructions.
Persons authorized to compile the technical file:
SAMSON AG, Weismüllerstraße 3, 60314 Frankfurt am Main, Germany
Frankfurt am Main, 13 December 2021
Stephan Giesen
Stephan Giesen
Director
Product Management
Classification: Public · SAMSON AKTIENGESELLSCHAFT · Weismuellerstrasse 3 · 60314 Frankfurt am Main, Germany
EB 8091 ES
Peter Scheermesser
Director
Product Life Cycle Management and ETO
Development for Valves and Actuators
Revision 00
Page 1 of 1
14-5