4 Remote control instructions for use
PLUS HOT AIR KEY
MINUS HOT AIR KEY
SWITCHING TO MANUAL MODE
AND AUTOMATIC MODE
NOTE:
1) During operation, the remote control must be pointed towards the stove.
2) When you are not using the remote control for a long time, remove the battery: CR2025.
5 Stove installation
• The stove must be installed on a suitable, solid, and level floor.
• The minimum diameter of a smoke duct is 80 mm, and it must be made of metal or other heat-resistant
materials and able to withstand a temperature of 220°C.
• The flue duct seal must be tight because the stove can only operate based on the pressure differential within
it and the draft in the chimney!
• Avoid deviating the connection from the upward direction to the downward direction. The horizontal pipes
must be inclined by about 3 to 5°, the vertical pipes from a height of 3 metres, in order to create an adequate
differential pressure, but the total length of the pipes must be less than 8 metres.
• The flues should only be used for this stove, they should not be shared with other products.
• Flue pipes can only be made of heat and flame-resistant materials, such as silicon or mineral fibre materials.
• Do not place the duct outlet in an enclosed or semi-enclosed area, such as a carport, garage, attic, low area
and narrow corridor, etc. The duct outlet must be at least 10 metres away from flammable objects.
• It is forbidden to reduce the diameter of the installation, which must be equipped with a device preventing the
return of smoke and rain.
• The stove must be correctly connected to the smoke duct by the installer and must also be approved by
firefighters.
• Note: The installation of the stove must comply with local regulations and rules.
5.1 Fume Connection Duct
1. Measure and mark for the connection of the flue (take the floor protection plate as reference).
2. When crossing walls, it is necessary to comply with the regulations in force regarding the installation of
smoke ducts.