INSTALLATION
Before Installing
Before You Begin
IMPORTANT:
• Installer: In the interest of safety and to
minimize problems, read these installation
instructions completely and carefully before you
begin the installation process. Leave these
installation instructions with the customer.
• Customer: Keep these installation instructions
for future reference and the local electrical
inspector's use.
APPLIANCE DATA PLATE
• The appliance data plate contains the model and
serial number information and the electrical
requirements.
• It is located inside the hood behind the filters on
the back side of the chassis. Remove the filters to
view it.
All specifications subject to change without notice.
LG assumes no liability for changes to
specifications.
Product Specifications
General Specifications
All models
Fan speed
5
Filter
2 ea, Aluminum mesh filter
Total Connect
120 VAC, 60 Hz, 4 Amp.
Load
Light
120 VAC, 8 W LED light strip
Weight
Model
LSHD3689BD
LSHD3680**
HCED3615S
HCED3615D
Width
35 7/16"
(90 cm)
Weight
41.3 lb (18.7
kg)
Adjusting Maximum CFM Level
Local codes in some areas limit the maximum CFM
of installed range hoods. You can adjust the
maximum blower CFM of this hood to avoid the
need for an expensive make-up air kit. During
install, you can easily set the maximum blower
speed to one of two commonly specified CFM
levels. (See the chart). You may not need to adjust
the CFM of the hood. Check local codes for CFM
restrictions.
Model
LSHD3689BD
LSHD3089BD
LSHD3680**
LSHD3080**
HCED3615S
HCED3015S
HCED3615D
HCED3015D
CAUTION
• Disconnect the hood from the main power
supply prior to following the conversion
instructions. Failure to do so could result in
personal injury or damage to the product.
• After re-positioning the jumper and powering on
the hood, the CFM cannot be changed again.
1
Before installing the hood, access the PC
board located box on top of blower housing.
2
Remove 2 to 4 screws attaching PC board
cover.
LSHD3089BD
LSHD3080**
HCED3015S
HCED3015D
3
Change the plastic jumper position on the PC
29 15/16"
(76 cm)
board to set your desired maximum CFM.
38.6 lb (17.5kg)
INSTALLATION
Available
Default Max
Max CFM
CFM Level
Levels
600
290 or 390
5