INSTALLATION INSTRUCTIONS: Viewline 85 mm
Speedometer
2. Setting the unit (UNIT) and alarm threshold (Warn)
1. Activate T. 30 (8-pin - Pin1)
2. Deactivate T. 15 (8-pin - Pin4)
3. Press and hold Mode key (14-pin - Pin 12)
Activate T. 15
Release Mode key
Press and hold Mode key
By briefly pressing the Mode key, you can switch between 24h and 12h (AM/PM)
clock format.
Press and hold Mode key
Press Mode key briefly
Press and hold Mode key
Set alarm threshold is displayed; the first digit flashes.
Press Mode key briefly
The flashing digit increases by 1. If the flashing digit is "9", the display returns to
"0"
Press and hold Mode key
The next lower digit flashes.
Press Mode key briefly
The flashing digit increases by 1. If the flashing digit is "9", the display returns to
"0"
Continue until the complete alarm threshold is set.
Press and hold Mode key
Deactivate T. 15. This saves the unit and the alarm threshold in the display.