Get function table:
Basic function
Get Function
Length
Get-Contrast
8
Get-Brightness
8
Get-Sharpness
8
Get-Color
8
Get-Tint
8
Get-Volume
8
Get-Mute
8
Get-Input select
8
Get-Power
8
status: ON/STBY
Get-Remote
8
control
Get-Power Lock
8
Get-Button Lock
8
Get-Menu Lock
8
Get-Tiling Mode
8
Get-Tiling
8
Compensation
Get-Tiling H by V
8
monitors
Get-Tiling
8
Position
Get-ACK
8
Get-Thermal
8
Get-Power on/
8
off log
Get-Date
8
Get- Time
8
Optional function
Get Function
Length
Get-Contrast
8
Get-Sharpness
8
Get-Color
8
Get-Tint
8
Command
ID
Type
Code (ASCII)
g
a
g
b
g
c
g
d
g
e
g
f
g
g
g
j
g
l
g
n
g
o
g
p
g
q
g
v
g
w
g
x
g
y
g
z
g
0
g
1
g
2
g
3
Command
Type
ID
(ASCII)
Code (ASCII)
g
a
g
c
g
d
g
e
Command
Response Range
Code (Hex)
(Three ASCII bytes)
61
000 ~ 100
62
000 ~ 100
63
000 ~ 100
64
000 ~ 100
65
000 ~ 100
66
000 ~ 100
000: OFF (unmuted)
67
001: ON (muted)
6A
000~
000: STBY
6C
001: ON
000 : Disable
6E
001 : Enable
002 : Pass through
000 : Unlock
6F
001 : Lock
000 : Unlock
70
001 : Lock
000 : Unlock
71
001 : Lock
000 : OFF
76
001 : ON
000 : OFF
77
001 : ON
01x~09x: H monitors
78
0x1~0x9 : V monitors
000 : OFF
79
001~025
7A
000
000~100:
0~+100 deg C
30
-01~-99:
-1~-99 deg C
000
31
(See below note)
000
32
(See the Set-Date
command)
000
33
(See the Set-Time
command)
Command
Response Range
Code (Hex)
(Three ASCII bytes)
61
000 ~ 100
63
000 ~ 100
64
000 ~ 100
65
000 ~ 100
51
Comments
Gets Contrast value
Gets Brightness value
Gets Sharpness value
Gets Color value
Gets Tint value
Gets Volume value
Gets Mute ON/OFF status
See Set-function table
1. 2
digital for H monitors
nd
2.3
digital for V monitors
rd
This command is used to
test the communication
link.
For specific models only
For specific models only
For specific models only
For specific models only
Comments

Publicidad

loading