1 - WiFi pairing and On/Off
2 - Zone 1, RF pairing with
central unit no.1, Override
function
3 - Zone 1, RF pairing with
central unit no.2, Override
function
Override function
Briefly press the button assigned to zone 1 on the receiver unit.
You will hear a click in the receiver unit as confirmation that you
have overwritten the command for zone 1 (from On to Off or vice
versa). The corresponding LED will remain lit. This function is
used when the connection between the central unit no. 1 and the
receiver unit is lost.
Briefly press the button assigned to zone 1 again to change the
state of the zone/relay again (from On to Off or vice versa).
The procedure can be repeated for all 4 zones.
4 - Zone 3, RF pairing with
central unit no.3, Override
function
5 - Zone 4, RF pairing with
central unit no.4, Override
function