FAULT DIAGNOSIS
The following simple checks may be performed by the operator. If the machine is still not working, please contact your local
Service Agent:
Trouble
Machine fails to start – no power
Machine fails to pick up water
from the floor
Drum not rotating
Drum is rotating, but brushes are
not
Machine fails to spray solution
onto the floor
Motor makes a humming noise
but does not turn
The machine is vibrating
The steam generator does not
produce steam
*If the fuse blows several times, the machine should be checked by an authorised Service Agent
PLEASE REFER TO THE BACK OF THE MANUAL FOR PICTORIAL INSTRUCTIONS
7
Reason
Transport working lever is in bottom
position (see pictorial guide)
Motor overload protector has tripped
Transport wheels not raising off the
ground when handle lowered
Lack of voltage / electrical supply
Incorrectly fitted / damaged
recovery tank Blocked hose or wand
Worn brushes
Drum not rotating
Debris around drum or base of
machine
Debris around brushes
Faulty pump
Improper water hose connection
No solution in solution tank
Blocked jet
Blocked inline filter
Blocked filter or faulty valve in
solution tank
Debris around drum and base of the
machine
Bristles on the brushes are
deformed
No water in the water tank
Faulty pump
Steam nozzle clogged with limescale
Steam unit switch is Faulty
Check steam fuse F3, pump fuse F4
Thermostat (TST1) is tripped.
Thermostat (TST2) when reaching its
set temperature it trips
Remedy
Change to operating position (see pictorial
guide)
Wait for 1 hour to allow the motor
temperature to reach room temperature.
Then try again
Check for debris and clean machine
Check fuse *, power cord, plug and socket
outlet
Refit or replace recovery tank
Check brush pressure, if needed replace
brushes
See below
Clean drum and base of the machine.
Clean or replace brushes
If there is no noise present from the pump,
check that the pump cable is fitted
correctly.
Check the quick lock connector for proper
fitting
Fill solution tank
Clean jet
Clean inline filter
Clean / replace filter or valve
Clean drum and base of machine
Soak brushes in a bucket of water
Replace both brushes
Fill with clean cold water.
Contact service agent
Descale
Contact service agent
If the fuse is blown, replace it with the same
rating. (If fuse blows again please contact
service agent.)
Please contact a service agent.
It will self reset automatically and normal
operation will resume.
(02-24)