Problem
A.
Restricted air flow or no air
flow
B.
Filter warning light is on
C.
The turbine has no power
D.
Excessive arcing/sparking in
the turbine
Patents
These products are covered by one or more of the following U.S. patents:
5,550,336
5,556,255
Titan 30-Day Satisfaction Guarantee
If, within a 30-day period from the date of purchase, you are not totally satisfied with a TITAN unit, you may return it for full credit
toward another TITAN product of equal or greater value.
© Titan Tool Inc. All rights reserved.
Troubleshooting
cause
1.
Air flow adjustment knob on the spray gun
is turned off
2.
Air filters are clogged
1.
Air filters are clogged
1.
No power at the power supply
2.
The fuse is blown
3.
Worn turbine brushes
1.
Worn turbine brushes
2.
Damaged commutator
5,639,222
5,702,131
United States Sales & Service
Phone:
1-800-526-5362
Fax:
1-800-528-4826
1770 Fernbrook Lane
Minneapolis, MN 55447
www.titantool.com
Solution
1.
Adjust the air flow adjustment knob
2.
Clean or replace the filters
1.
Clean or replace the filters
1.
Check the power supply
2.
Check and replace the fuse
3.
Have the brushes replaced at an authorized Titan
service center
1.
Have the brushes replaced at an authorized Titan
service center
2.
Replace the turbine (contact a Titan service
technician)