4
TECHNICAL SPECIFICATIONS
a. Battery
- Rated voltage: 12V
- Rated battery capacity: 40 Ah
- Operating temperature: -20°, +55°C
- Dimensions: 195 x 170 x 160 mm
c. LED light
- Rated voltage: 12V
- Maximum power: 10W
- Operating temperature: -20°, +50°C
- Luminous flux: 280 to 330 lm
- Base: E27
5
MAINTENANCE
It is advisable to clean the panel regularly for optimum recharge capacity. The guarantee is void if parts have been
dismantled. Clean the outside with a soft dry cloth only.
Warning: Do not use any carboxylic acid or alcohol-based or other similar product or solvent. In addition to
the risk of damage to your device, fumes are also dangerous to health and are explosive.
For cleaning purposes do not use any tool that may act as a voltage conductor (e.g. metal brush or sharp tool) or
that could potentially scratch the glass.
Disposal of the battery: The battery contains pollutants and must not be thrown away in the household rubbish
after removing it from the installation. It must be disposed of or recycled by one of the methods provided for by
the legislation currently in force in your country.
6
TECHNICAL ASSISTANCE - GARANTEE
Fault
- The battery is often dis-
charged
- LED1(green)fast flashing
- LED3 (red) ON, but load
are not supplied
- LED3(red) fast flashing,
and load are not supplied
- LED3(red) slow flashing,
and load are not supplied
- LED2 is red led On, and
load are not supplied
GB
b. Photovoltaic solar panel
- Rated voltage: 18V
- Maximum power: 40W
- Operating temperature: -40°, +85°C
- Dimensions: 675 x 490 x 30 mm
- Weight: 4,8 kg
Cause
- Battery is not being charged
during the day
- Overvoltage of system voltage
- Panel incorrectly orientated
- Panel incorrectly wired
- Short circuit of loads
- Overload of loads
- Battery has low capacity
CFI EXTEL SUNPOWER 40 - 04/2011 - V1
c. Charge controller
- Rated voltage: 12V
- Charging current max. 10A
- Operating temperature: -20°,
+55°C
Solution
- Remove solar array fauty connecton/
reverse polarity
- Wiring error
- Check the load wires leading
- Check all the wiring and the condition of
the wires and cables
- Reduce the number or power of the
appliances connected to the kit
- Recharge the battery with an external
charger.
- Wait until the panel has finished recharging
the battery