SPECIAL SAFETY INSTRUCTIONS
Keep water away from any electrical parts of the power tool and from persons in the working area.
Never use the machine without a PRCD.
1 Be operated using an PRCD. The machine may only operated using a PRCD with a max. rated fault current of 10 mA.
2 Use gloves. Use special safety glove all time to reduce personal injuries.
3 Wear rubber boots (for insulation) when performing cleaning work.
3 Use hearing protection. Noise level when working can exceed 88 dB (A). Use ear protection all time!
4 Wear eye protection. When working with power tools there is a risk of floating soil. Wear eye protection to reduce
eye injuries.
5 The drain cable must be removed completely from the holding cage before machine is turned on.
6 Before inserting the plug into the electrical socket, make absolutely sure that the pipe cleaning machine is switched
to 0 or OFF.
7 To prevent damage, use this machine and its accessories only to clean waste water pipes — never chimneys, wells,
etc.
8 To prevent damage to the pipes or pipe bends, do not modify tools by sharpening them, etc.
9 Use a camera system to spot the cause of the pipe clog.
DESCRIPTION (FIG.1 et 2)
1 Guide hose
2 Protecting cap
3 Clutch and transport handle
4 Drain cable
5 Tool
6 On / Off switch
7 Power cable
TECHNICAL DATA
Voltage :
......................................................................................................................................................................
Rated power cons. :
Operating speed :
Working range :
...........................................................................................................................................
Max. working length :
Weight :
.......................................................................................................................................................................................
Typical weighted acceleration in the hand-arm area :
Sound pressure level (L
Sound power level (L
Protection class :
Noise level when working can exceed 88 dB (A). Use ear protection!
The typical weighted acceleration in the hand-arm area can exceed the declared value of 2,5 m/s². If you observe
increased vibrations stop working with power tool. Check the machine for dynamic unbalance.
WARNING: The drain cleaning machines are only designed for short term operation and may therefore only be
used for maximum continuous of 15 minutes (15 minutes work / 45 minutes break)
...........................................................................................................................................................
...........................................................................................................................................................
..........................................................................................................................................................
)
.......................................................................................................
pA
)
..........................................................................................................
WA
......................................................................................................................................................................
EN
8 PRCD
9 TEST switch
10 Indicator light
11 RESET switch
12 Male connector
13 Female connector
14 Decoupling key
.........................................................................
72 dB (A) | K
85 dB (A) | K
Page 8
230 V, 50 Hz
750 W
690 rpm
Ø 50 – Ø 150 mm
70 m
26 kg
2
< 2,5 m/s
3 dB (A)
pA
3 dB (A)
WA
IP44