to be found on the unit type plate or on the packaging, or in this manual.
• Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
• Extension cables and power distributors (e. g. outlet strips) must be suitable for outdoor use.
• Minimum safety distance between the unit and the water: 6.5 ft.
• Protect the plug connections from moisture.
• Only plug the unit into a correctly fitted socket.
Safe operation
• Never operate the unit if either the electrical cables or the housing are defective!
• Do not carry or pull the unit by its electrical cable.
• Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do not present a
tripping obstacle.
• Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
• Only execute work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
• Only use original spare parts and accessories for the unit.
• Never carry out technical modifications to the unit.
• The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
• Only operate the unit if no persons are in the water!
• The unit, the connections and plugs are not water-proof and must not be routed or installed in water.
• Keep the socket and power plug dry.
• Ensure that the filter will not overflow. Danger of emptying the pond.
Installation (A)
Saw off the stepped hose connection in accordance with the hose diameter used (A1). At the filter, push the union nuts
over the stepped hose connections, push or turn on the stepped hose connection, and secure with the hose clips.
Place the flat sealing rings in the union nuts and screw onto the inlet and outlet of the pressure filter (A2
Installation (B)
Place the pressure filter in a flood protected position at a distance from the pond edge of at least 2m on firm and level
ground. As an alternative, the filter can also be partly buried up to approx. 5 cm below the closing clamps. The height
difference between the lid and the free outlet point may be max. 2 m. Do not expose the unit to direct sun radiation.
Ensure direct access to the lid to be able to carry out work at the unit.
Start-up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Attention! Never operate the unit with a water pressure of more than 3 psi!
Attention! Never operate the unit without water flowing through!
Adhere to the safety information given above! Connect the filter pump (not included) power plug (C1) and wait until the
pressure filter is filled with water. Check the pressure filter container and all connections for leaks. Connect the power
plug of the UVC clarifying unit, the blue control lamp is lit (C2). Fit the cover of the UVC pre-clarifying unit. Note: After a
new instal- lation, the unit only reaches its full biological cleaning effect after a few weeks. The full effect on bacteria is
only reached as from a water temperature of + 50 °F. Note: In the event of overheating, the installed temperature
monitor switches the UVC lamp off automatically, the lamp automatically switches on again once cooled down.
Switching off: Disconnect the power plug
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water: