Specifications
Display: 3-3/4–digit LCD (4000 maximum count) and 42-segment bar graph
Sampling Rate:
Numeric Display: 1.5 per second
Bar Graph Display: 13 per second
Jaw Opening: 34 mm (1.34")
Measurement Category: Category III, 600 V
Temperature Coefficient: 0.2 x (Accuracy) per °C above 28 °C or below 18 °C
Operating Conditions:
Temperature:
0 °C to 30 °C (32 °F to 86 °F), 0% to 80% relative humidity, noncondensing
30 °C to 40 °C (86 °F to 104 °F), 0% to 75% relative humidity, noncondensing
40 °C to 50 °C (104 °F to 122 °F), 0% to 45% relative humidity, noncondensing
Altitude: 2000 m (6500') maximum
Indoor use only.
Storage Conditions: –20 °C to 60 °C (–4 °F to 131 °F),
0% to 70% relative humidity, noncondensing
Remove battery (or batteries).
Pollution Degree: 2
Battery:
CM-800: Two 1.5 V AA batteries (NEDA 15A or IEC LR6)
CM-850: One 9 V battery (NEDA 1604, JIS 006P, or IEC 6F22)
Battery Life:
CM-800: Approximately 600 hours with alkaline batteries
CM-850: Approximately 200 hours with alkaline battery
CM-800 • CM-850