Descargar Imprimir esta página

Thermador UCVM Serie Manual De Instalación página 11

Ocultar thumbs Ver también para UCVM Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Step 3: Prepare Duct Cutouts in
Cabinet
Y A. Refer to Figure 8. Drop a plumb-line
from Point "P" at the rear center of the
countertop cutout. Mark this point on the
bottom of the cabinet below. Construct
two reference lines through this point:
one should be parallel to the cabinet
front and directly below the rear counter-
top cutout (Line A-A), and the other (Line
B-B) should be at right angles to A-A.
Y B. Using these reference lines as a base
for the measurements, layout the neces-
sary cabinet cutouts needed to imple-
ment the planned ductwork route. Where
a range of measurements is noted,
choose a measurement that allows best
clearance from wall studs, floor joists,
utilities, or other obstructions.
Point "P"
Center Line (CL)/
Plumline
Step 3: Prepare Duct Cutouts in
Step 3: Cabinet
Y C. Before cutting for ducting, temporarily
Y D. Remove temporarily placed hardware
Y E. Make all other cabinet modifications
Note: Check boxes as tasks are completed.
set intake and cooktop in place and
attach integral blower (or duct transition
fitting if a remote or inline blower is instal-
led). Refer to steps 6 and 7. Verify that
the duct cutouts as marked will match
the hardware installation. Adjust the duct
cutout as necessary to match hardware
installation.
and make cutouts in cabinet to accom-
modate ductwork installation.
needed to provide proper clearances for
drawers or removable shelving.
Fig. 8