4
LINE INPUT (LEFT/RIGHT)
Unbalanced RCA line input.
5
LINE INPUT (LEFT/RIGHT)
Balanced XLR/6.3 mm jack (combo) line input.
6
SAT POWER OUT (LEFT/RIGHT)
Powered Speakon compatible output for LD DAVE G³ series.
7
LINE DIRECT OUTPUT (LEFT / RIGHT)
Balanced XLR output which allows you to connect active loudspeakers etc. Provides same signal as input
signal.
8
POWER
Power ON/OFF switch. Before switching power on, all level controls should be set to minimum.
9
MAINS SOCKET (VOLEX POWER PLUG)
With built-in fuse holder AC connection via IEC connector (220 - 240V AC).
A power cord with a lockable Volex connector is supplied with this unit.
IMPORTANT: Replace fuse only by fuse of same type and rating! If fuse blows repeatedly please contact
authorized service center!
10
ON LED
Lights up when power is switched on and mains cable is connected correctly.
11
SIGNAL LED
Lights up when the unit receives an audio signal.
12
LIMIT LED
Lights up when the loudspeaker is operated at it's limit. Short-term blinking of the LED is not critical.If the
limiter LED lights up longer than a brief moment or permanently (= over-driving the system), reduce the
volume of the connected signal source. Non-compliance will lead to unpleasant and distorted sound and
may cause malfunction of the speaker system.
13
PROTECT LED
Lights up in case of unit overload/overheating. Amplifier switches to mute automatically. The unit will return
to operation mode under normal conditions after a few minutes.