8. MAINTENANCE
Maintenance and Cleaning the Unit
•
Make sure the area below the installation place
is free from unwanted persons during setup.
•
Switch off the unit, unplug the main cable and
wait until the unit has cooled down.
•
All screws used for installing the device and
any of its parts should be tightly fastened and
should not be corroded.
•
Housings, fixations and installation spots (ceil-
ing, trusses, suspensions) should be totally free
from any deformation.
•
The main cables must be in impeccable condi-
tion and should be replaced immediately even
when a small problem is detected.
•
It is recommended to clean the front at regu-
lar intervals, from impurities caused by dust,
smoke, or other particles to ensure that the
light is radiated at maximum brightness. For
cleaning, disconnect the main plug from the
9. TROUBLESHOOTING
Problems
Fixture does not light up
General low light intensity
Fixture does not power up
P. 8
Neo Elipsoled Lite 50 - English version
Possible causes
• No mains supply
• Dimmer fader set to 0
• All color faders set to 0
• Faulty LED
• Faulty LED board
• Dirty lens assembly
• Misaligned lens assembly
• No power
• Loose or damaged power cord
• Faulty internal power supply
socket. Use a soft, clean cloth moistened with
a mild detergent. Then carefully wipe the part
dry. For cleaning other housing parts use only
a soft, clean cloth. Never use a liquid, it might
penetrate the unit and cause damage to it.
Fuse Replacement
1. Disconnect this product from the power outlet.
2. Remove the safety cap by a screwdriver.
3. Replace the blown fuse with a fuse of the exact
same type and rating (T1A,250V).
4. Install the safety cap, and reconnect power.
Checks and remedies
• Check the power supply voltage
• Increase the value of the dimmer channels
• Increase the value of the color channels
• Replace the LED board
• Replace the LED board
• Clean the fixture regularly
• Install lens assembly properly
• Check for power on power outlet
• Check power cord
• Replace internal power supply