System errors
Total Fixture hours
Partial Fixture hours
Total lamp hours
Partial lamp hours
Error information
Reset fail, uart error
Pan reset fail
Tilt reset fail
Pan Hall error
Tilt Hall error
Motor Colour reset fail
Motor Gobo reset fail
Lamp control fail
lamp hours too long, pls replace
Advanced interface
In hear to set a password, to prevent the non-spe-
cialize person to faulty operate. Default password
is "UP DOWN UP DOWN". Press "Enter" to verify the
password.
Option
Sensor Monitor
P. 6
Tecshow Halo 1R | English version
If the red ERR indicator light light on, it means fixture running error, and enter
the sub-surface to check the details. Press "Clear" to empty the error record
after finish check. Note: Sometimes it not the installation problem of Hall or
optocoupler. It is because the motor cable inversely connect.
Total using hour (accurate to minute)
The using hour from the power on (accurate to minute)
Total lighting hour (accurate to minute)
This time lighting hour (accurate to minute)
Driver board no respond. There is problem in the uart communication
line of display board and driver board. Or the driver board problem.
X photoelectric switch, or X Motor problem.
Y photoelectric switch, or Y Motor problem.
Problem in X Hall.
Problem in Y Hall.
There is problem in Color wheel hall, or Color wheel motor.
There is problem in Gobo wheel hall, or Gobo wheel motor.
Lamp light on or off fail, there is problem in ballast or lamp.
The total lamp light hour over the Maximum lamp light hour in "high
class" menu. Remind the user change the lamp in time. And then clear
the lamp light hour in "high class", timer reset.
Tilt Hall state
Color hall state
Gobo hall state
Pan codewheel state
Tilt codewheel state
Pan codewheel step
Tilt codewheel step
Instruction
Instruction
0 means the magnet closure, 1 means the magnet stagger.
0 means the magnet closure, 1 means the magnet stagger.
0 means the magnet closure, 1 means the magnet stagger.
2digit, each digit corresponding to the photoelectricity
switch on the coding disc.
2digit, each digit corresponding to the photoelectricity
switch on the coding disc.
Running in positive direction, the step value adding, Run-
ning in negative direction, the step value reduced.
Running in positive direction, the step value adding, Run-
ning in negative direction, the step value reduced.