Type of
Rated current for light load
Application for LIFTS - INTERMITTENT duty (*)
Maximum starting current
Ambient temperature 0 ÷ 50°C . Degree of protection IP20
(*) Duty is considered intermittent where the motor drive starts for a duration below or equal to 60" each 120".
*Consider the real currents of the system, sometimes the real currents are higher than the ones on the data plate.
If the motor data is available, consider the imax (starting current with full load on ascent with cold oil).
In order to protect the power component (SCR) and to avoid dangerous conditions
in the event of a short circuit, you are advised to install, upstream of the power line
(L1-L2-L3), 3 fuses with an I²t the the one is supported by the SCR.
The fuses shown in the Table ensure Type 2 protection.
Type of
SMS-Hstart
SSW105
SSW160
The electrical connections to the
isolations and maximum temperatures allowed by the cables.
The Table shows the minimum cross sections, where FS17 type cables are used.
Power terminals L1-L2-L3-U-V-W
Command terminals 1-2-3-4-5
SMS-Hstart
can be connected either on the line that powers the motor (Fig. 1), or inside the delta
of the motor (Fig. 2), if you are using a motor with the windings connected in delta when powered
by mains voltage (i.e. 400/690 motor with 400V mains power or 230/400 motor with 230V mains
power).
When
SMS-Hstart
is connected to the delta, the current passing through it (IF) is 1.6 times lower
than the line current (IL). It can therefore be used for motors with a rated current 1.6 times greater
rated current.
(*)
Considering the 3rd harmonic in the triangle
10
TECNICAL FEATURES
PROTECTION FUSES
I²t SCR @
45°C
ITALWEBER
25.000
145.000
CONNECTIONS
SMS-Hstart
device must be carried out in accordance with the
CONNECTIONS MOTOR
Code
Type
ITALWEBER
BS88
1743149
BS88
1743250
ATTENTION:
IN CASE OF 230V POWER SUPPLY,
MOVE THE CONNECTOR ON
THE BOARD TO 220
SSW105
16mm²
0,75mm²
SSW105
SSW160
105A
160A
200A
360A
I²t Fuse
11000
53000
SSW160
35mm²
0,75mm²
REV. 1 Printed 02/2020