Control de señales de entrada y salida
PS connection (NPN/PNP/push-pull) with internal power supply:
Connector CON2 (PS/encoder)
(Product sensor, 7-pin)
+Ub external
+Ub internal
PS input
GND internal
GND external
J2 is to be inserted into 2-3 (default)
Figura 11
PS connection (electronical or mechanical relais) with internal power supply:
Connector CON2 (PS/encoder)
(Product sensor, 7-pin)
+Ub external
+Ub internal
PS input
GND internal
GND external
J2 is to be inserted into 2-3 (default)
Figura 12
Encoder connection with internal power supply:
Connector CON2
(Product sensor, 7-pin)
+Ub external
+Ub internal
Enc. 'A'
Enc. 'B'
GND internal
GND external
With left-handed rotation of the encoder Pin3 must be exchanged with Pin7!
Figura 13
24

7.4 Suministro de voltaje interno

4
x
Prod.sensor
5
x
6
x
1
x
2
x
4
x
Prod.sensor
5
x
6
x
1
x
2
x
4
x
(brown/green)
5
x
3
(brown)
x
7
(green)
x
1
x
(white/green)
2
x
Manual de usuario
(DC coupled)
CON2
4
x
1
5
PNP
x
6
x
or
e.g.:
1N4003,1N4148
1
x
NPN
2
x
(DC coupled)
CON2
4
x
5
x
6
x
1
x
2
x
(DC coupled)
Encoder (right-handed rotation)
A2
B2
Dynacode IP
Prod.sensor
2
2
Prod.sensor
11.18