PREPARATION
(cont.)
NOTICE: The T-5501 is equipped with a 1/4" NPT air
coupler. If installing a different air coupler, ensure thread
tape or compound is used when servicing connections.
To ensure dependable, trouble free operation an inline
air dryer and oiler is recommended.
6. Pump mechanism should operate smoothly before
putting jack into service. Replace worn or damaged
parts and assemblies with Pro-Lift authorized
replacement parts only.
Bleeding/Venting Trapped Air
With the Release Valve in the OPEN position (step 3b,
pg. 3) and Ram fully lowered, locate and remove the oil
filler screw. As screw is removed, pressurized air may
be heard escaping from the reservoir.
!
CAUTION: Reservoir may be under pressure and
hydraulic oil may be expelled.
This means trapped air has been successfully removed
from the system. With Lift Pedal in the sleeve, pump 6
to 8 full strokes. This will help release any pressurized
air still trapped within the reservoir. Oil level should be
even with the bottom of the oil filler hole. Reinstall the
oil filler plug/screw.
ASSEMBLY
1. Install Hydraulic Unit on receiver and secure with
provided M8 x 1.25 bolts (ref. Figure 2).
2. Insert Ram pin through Ram and Ram brackets on
crosshead assembly, then install cotter pin.
3. Insert Release Valve through Release Valve guide and
attach to Hydraulic Unit with screw and nut provided.
4. Insert Lift Pedal into Sleeve and attach with supplied
bolt.
5. Install Positioning Handle into frame and secure using
the provided pins (2).
6. Attach two Wheel Baskets to sides of Lift Platform
(ref. Figure 3).
7. After assembly, ensure that lift rolls, lifts and locks,
and that pump operates smoothly before putting into
service. Familiarize yourself with how Height Locking
Lever, Lift Pedal, and the Height Unlocking Lever
operate prior to loading lift. Replace worn or damaged
parts and assemblies with
parts only
(ref. Replacement Parts, pg. 6). Lubricate
as instructed in Maintenance Section.
OPERATION
1. Adjust Wheel Baskets to their correct position.
2. Drive mower onto Wheel Baskets.
authorized replacement
WARNING: Use only on hard, level surface capable
!
of supporting the load.
3. Leave mower transmission in neutral, close Hydraulic
Release Valve. Carefully pump jack until mower
reaches desired height. Final height must correspond
with the locking teeth on the Height Locking Lever.
4. Carefully turn the Release Valve counterclockwise
until the Lift Platform engages the Height Locking
Lever, then close the Release Valve by turning it
fully clockwise. Do not work around or under load
unless Height Locking Lever is properly engaged.
5. Secure the mower by setting the parking brake, putting
transmission in gear and chocking the wheels.
!
CAUTION: Clear all tools and personnel before
lowering load. Only attachments and/or adapters
supplied by the manufacturer shall be used with
this device.
6. To lower the Lift Platform, release the mower's
parking brake, place transmission in neutral and
remove chocks. Pump the Lift Pedal several times
to disengage the Height Locking Lever.
MAINTENANCE
Keep lift clean and well lubricated. Apply a couple of
drops of light machine oil to all pivoting joints as needed.
Thoroughly wipe up excess oil.
NOTICE: Use premium quality hydraulic jack oil. Avoid
mixing different types of fluid and NEVER use brake
fluid, turbine oil, transmission fluid, motor oil or glycerin.
Improper fluid can cause failure of the jack and the
potential for sudden and immediate loss of load.
Adding oil
1. To check hydraulic oil level, unload lift, lower Lift
Platform completely, then remove Hydraulic Unit from
lift. Place Hydraulic Unit upright on a stable, level
surface. Locate and remove Oil Filler Plug.
2. Ensure the oil level is
Reinstall the Oil Filler
Hydraulic Unit onto receiver. Secure with provided
bolts.
Changing oil
For best performance and longest life, completely replace
the hydraulic fluid supply at least once per year.
1. With Lift Platform fully lowered, remove Hydraulic Unit
from lift. Place Hydraulic Unit upright on a stable, level
surface. Remove the Oil Filler Plug.
2. Lay the unit on its side and drain hydraulic fluid into a
suitable container.
4
even with the Oil Filler Plug hole.
Plug, then
install