Product Disposal; Battery Disposal - Stobag SRCK 650 Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
To cancel blocks generated during the test phase, simply switch off the control unit
(or motor) controlled by SRCK 650 for a few seconds.
On completion of the checks in TEST mode, the Sun and Wind sensor knobs can be set
to the required values, using the graduated scale next to the knobs as a reference.
• "Sun" knob
As a guideline, this knob should be set to between 15 and 30Klux. If the automation
needs to be activated in the case of very intense sunlight, set the knob to a higher
value.
Otherwise, the "real time" mode can also be used to set the Sun knob. To use this
mode, turn the Sun knob through small sections and each time wait for a few seconds,
to that SRCK 650 can compare the set threshold with the light value measured at that
time, and then transmit the envisaged command to the motor. In this case the led emits
one of the following signals: green flashing = threshold exceeded; alternating red and
green flashes = threshold not exceeded.
• "Wind" knob
As a guideline, this knob should be set to between 15 and 30Km/h; it can only be set to
higher values in the case of small and very sturdy awnings.
7 – DIAGNOSTICS
It is possible to check at any time whether the intensity of the atmospheric phenomena
at the time is below or above the set threshold by activating "DIAGNOSTIC" mode.
To activate diagnostics, briefly press "P1" (fig. 2) and wait for approx. 1 second when
the red led stops flashing, then check the led signal and compare this with the descrip-
tion in Tabla A.
Caution! - "Diagnostic" mode only generates the led signal and not an awning
command.
Table A
• Led off: No threshold has been exceeded and there is no pre-alarm.
• Red Led lit (for 3 seconds): The set wind threshold has been exceeded
• Green Led lit (for 3 seconds): The set sun threshold has been exceeded
• Red flashing Led (for 3 seconds): Pre-alarm – fault on "wind" sensor this has not
detected wind action in the last 24 hours
• Green flashing Led (for 3 seconds): Pre-alarm – fault on "sun" sensor this has not
detected any variation in sunlight intensity in the last 24 hours
www.stobag.com
8 – DISABLING THE SUN SENSOR
To disable the sun sensor, for example in the winter, turn the "Sun" knob (fig. 2) clock-
wise to the maximum setting. To enable the sensor, turn the knob to the required setting
and briefly press "P1" (fig. 2).
Caution! - The wind sensor cannot be disabled.
9 – TROUBLESHOOTING...
If the wind or sun exceeds the set threshold but the motor seems not to per-
form the ma n oeuvre correctly: • ensure that SRCK 650 is correctly memorised in
the receiver of the motor to be controlled, as follows: Send a command to the motor by
means of another transmitter, then press P1 on SRCK 650 to ensure that the manoeu-
vre is stopped. • Check correct operation of the sensors by running the diagnostics
function described in chapter 7. • Then perform the TEST de scribed in chapter 6.
PRODUCT DISPOSAL
This product is an integral part of the automation, and therefore must be dis-
posed of together with the latter.
As in installation, also at the end of product lifetime, the disassembly and scrapping
operations must be performed by qualified personnel.
This product comprises various types of materials: some may be recycled and others
must be disposed of. Seek information on the recycling and disposal systems envisaged
by the local regulations in your area for this product category.
Caution! - some parts of the product may contain pollutant or hazardous substances
which, if disposed of into the environment, may cause serious damage to the environ-
ment or physical health
As indicated by the symbol alongside, disposal of this product in domestic
wa ste is strictly prohibited. Separate the wa ste into categories for dispos-
al, according to the methods envisaged by current legislation in your area,
or return the product to the retailer when purchasing a new version.
Caution! – Local legislation may envisage serious fines in the event of
abusive disposal of this product.
Battery disposal
Caution! – The product contains a battery that must be removed prior to disposal. The
discharged battery contains pollutant substances and therefore must not be disposed
of as common household waste. Dispose of according to separate waste collection
procedures as envisaged by local current standards.