SCHEMA DE REGLAGE DES ELECTRODES/SONDE IONISATION
1- Electrode ionisation
2- Electrode allumage
3- Disque flamme
4- Mélangeur
5- Tuyau de refoulement du gaz
REGLAGE DES CAMES DU SERVOMOTEUR SQN72.6A4A20
PIVOT D'ACTIVATION ET DESACTIVATION ACCOUPLEMENT MOTEUR
- ARBRE CAMES
I
OUVERTURE MAXIMALE AIR (90°)
II
FERMETURE TOTALE AIR (BRÛLEUR ARRÊTÉ) (0°)
III OUVERTURE MINIMALE AIR (INFERIEURE A LA CAME (10°)
IV OUVERTURE AIR D'ALLUMAGE (SUPERIEURE A LA CAME III)
(20°)
POUR MODIFIER LE REGLAGE DES CAMES UTILISEES, ON AGIT SUR
LES ANNEAUX RESPECTIFS (I -II - III - IV). L'INDEX DE L'ANNEAU
INDIQUE SUR L'ECHELLE DE REFERENCE RESPECTIVE L'ANGLE
DE ROTATION SELECTIONNE POUR CHAQUE CAME.
TBG 45 PV / PNV
TBG 60 PV / PNV
ECHELLE DE REFERENCE
12 / 26
0006081484_201104
Mod.
A
B
C
TBG 45 PN-V
4
5
4
TBG 60 PN-V
4
10
-
CAMES REGLABLES
INDICATEUR DE POSITION