M
Ounting the stOve On a wall
Place the wall bracket (1) on the wall at the desired height. Allow for a 4 cm distance as a minimum from
the floor to the bottom of the mounted wall bracket. Using a pen, mark six to eight of the holes (2) in
the wall fittings on the wall and drill the holes. It is important that the wall fittings are not screwed into
a joint in the wall. If the flue duct is connected to a rear smoke outlet, mark the large hole (3) in the wall
fittings. Measure up, working from the centre of the large hole (3) in the wall fittings to ensure that the
hole fits the wall bushing. Mark the hole on the wall and drill. Tighten the wall fittings to the wall, using
steel Rawlplugs. It is very important that the fittings are completely level.
Lift the top plate (11) off the wood-burning stove. Remove the rear plate (4) from the stove by loosening
the two screws (5) at the top of the fittings above the rear plate and lifting the rear plate off the hooks
(6) at the bottom. Break off the two oblong excisions (12) at the top of the rear plate. If the wood-
burning stove needs to be connected to a smoke pipe at the rear, the pre-cut cover plate (7) on the rear
plate should also be removed. Return the rear plate to its hanging position in the stove, so that it grips
the two hooks at the bottom (6) and fits under the two fittings (8) at the top. Tighten the two screws
(5) at the top through the fittings and the rear plate, so that the rear plate is fastened again.
Lift the stove up onto the two hooks (13) on the wall fitting. For proper fitting, make sure that the stove
rests securely in the hooks. Put the oblong cover plate (10) on top of the wall fittings, and screw it (14)
into the stove's wall fittings. This locks the stove into the wall fitting. Do not overtighten the bolts, as the
metal should be able to expand with the heat generated by normal use of the stove.
Building material Producer Type and designation
Concrete,
solid brick or
hollow brick
Air-entrained
concrete
The wall's plaster work is not accounted for in the sizes listed above. The anchor's effective length must
therefore be increased by at least the minimum thickness of the plaster work.
Important! The wall fitting may not be screwed into brick joints.
Hilti
HUS-H 10,5 x 55
Expandet
MMS-S 7,5 x 50
Fischer
FBS 8/5 US
Expandet
LB metal M10 air-entrained concrete anchor
Fischer
FTP M 10 + set screw M10 x 25 mm steel
e