Page 5
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
Fan
WHT
BLK
120 VAC
LINE IN
GRD
MANUAL-ON
SENSOR/CONTROL
BLACK
WHITE
ORANGE
MANUAL - ON
SENSOR / CONTROL
MULTI-FUNCTION
WALL SWITCHES
(purchase separately)
Attach cable clamps to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Light
2
Connect wires
LIGHT
NIGHT-LIGHT
MULTI-FUNCTION
WALL SWITCHES
RED
GROUND
(green or bare)
BLUE
BROWN
SWITCH
BOX
LIGHT
NIGHT
LIGHT
120 VAC
LINE IN
WHT
BLK
RED
RED
14/3
14/3
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
RED
ORG
BLK
WHT
GRD
LIGHT RECEPTACLE WIRES
RECEPTACLES
KNOCKOUT
PLATE
FAN RECEPTACLE
WIRES
XB110HL Installation Guide
3
4
Screw from
Parts Bag
WHT
BLU
LIGHT
NIGHT
LIGHT
RED
FAN
BLK
SENSOR/
CONTROL
BRN
WHT
• See OPERATION section on page
12 for details.
• SENSOR/CONTROL switch turns
humidity control on for automatic
operation and off for fan cleaning
and maintenance purposes.
• MANUAL-ON switch directly turns
fan on/off.
• MANUAL-ON switch is not required
to manually turn fan on (see page
10).
• SENSOR/CONTROL switch may
be located where it is not easily
accessed for everyday usage; it
may need to be labeled and located
where it can't be turned on without
being seen from fan to comply with
local and national codes.