Broan ULTRA SILENT QTXE Serie Manual De Instrucciones
Broan ULTRA SILENT QTXE Serie Manual De Instrucciones

Broan ULTRA SILENT QTXE Serie Manual De Instrucciones

Ocultar thumbs Ver también para ULTRA SILENT QTXE Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

QTXE SERIES
ULTRA SILENT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with the homeowner.
MODELS QTXE050 • QTXE080 • QTXE110 • QTXE150
FANS
TM
To register this
product visit:
www.broan.com
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch or speed control to operate this ventilator. See
"Connect Wiring" for details. Use of speed controls other than the
Broan Models 78V and 78W may cause a motor humming noise.
WARRANTY
BROAN THREE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period
of three years from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE.
During this three-year period, Broan will, at its option, repair or replace,
without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal main-
tenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other
than by Broan), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation
on how long an implied warranty lasts, so the above limitation may not
apply to you.
BROAN'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN'S OP-
TION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY
UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCI-
DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan at the address
or telephone number stated below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC
Hartford, Wisconsin
www.broan.com
800-558-1711
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan ULTRA SILENT QTXE Serie

  • Página 1 To qualify for warranty service, you must (a) notify Broan at the address or telephone number stated below, (b) give the model number and part 4. Please read specification label on product for further informa- identification and (c) describe the nature of any defect in the product or tion and requirements.
  • Página 2: Typical Installations

    MODELS QTXE050 • QTXE080 • QTXE110 • QTXE150 Page 2 TYPICAL INSTALLATIONS Housing mounted anywhere between Housing mounted to trusses using hang- er bars. I-joists. PLAN THE INSTALLATION Housing mounted any- where between COOKING AREA I-joists Do not install above or using inside this area.
  • Página 3 MODELS QTXE050 • QTXE080 • QTXE110 • QTXE150 Page 3 INSTALL HOUSING & DUCT 1a. Mount SCREW (2) HOLE FOR OPTIONAL housing to SCREW MOUNTING (4) joist or I-joist. Use a pliers to bend housing TABS out to 90 . Hold housing in place so that TABS the housing tabs...
  • Página 4: Service Parts

    97016466 Housing can be ordered on our 97016450 Duct Connector-6” website. Please visit 98010102 Wiring Plate us at www.broan.com 99170245 Screw, #8-18 X .375 97018010 Wire Panel/Harness Assembly 97017782 Blower Assembly (QTXE050) 97017783 Blower Assembly (QTXE080) 97017784 Blower Assembly (QTXE110) 97016591 Blower Assembly (QTXE150) 99140199 Grille Spring (2 req’d)
  • Página 5: Ventiladores Ultra Silenciosos Serie Qtxe

    Esta garantía sustituye todas las garantías anteriores. una echada de 12/12 (ángulo de 45 grados). NO MONTE ESTE Para tener derecho al servicio de la garantía, usted debe (a) notificar a Broan a la PRODUCTO EN UNA TECHO.
  • Página 6: Instalaciones Típicas

    MODELOS QTXE050 • QTXE080 • QTXE110 • QTXE150 Página 6 INSTALACIONES TÍPICAS Montaje de la cu- Montaje de la cubi- bierta en cualquier erta en viguetas “I” . parte entre armadu- ras por medio de barras de suspen- sión. PLANIFICACIÓN DE LA Montaje de la cubier- ta en cualquier parte INSTALACIÓN...
  • Página 7: Instale La Cubierta Y El Conducto

    MODELOS QTXE050 • QTXE080 • QTXE110 • QTXE150 Página 7 INSTALE LA CUBIERTA Y EL CONDUCTO 1a. Instale la ORIFICIO PARA MONTAJE TORNILLO (2) cubierta en CON TORNILLO OPCIONAL (4) las viguetas o viguetas “I” . Con un alicate, doble las LENGÜETAS de la cubierta a 90°.
  • Página 8: Conexión Eléctrica

    97016466 Cubierta pueden ahora pedir en nuestro 97016450 Conector del conducto (6 pulg.) Web site. Visítenos por favor en 98010102 Placa de cableado www.broan.com 99170245 Tornillo n. 8-18 x 0.375 97018010 Conjunto del panel de cableado/arnés 97017782 Conjunto del ventilador (QTXE050)

Tabla de contenido