Operating the Dishwasher
SHE6AP, SHE6AF
To start the dishwasher:
Door must be closed. Press the "ON/OFF" button.
The Countdown Display and one of the Wash Cycle
LEDs will be flashing. You can now select a wash
cycle.
Press the "<" or ">" button to select the desired wash
cycle.
Select the "Half Load" ("Top Rack only" in select
models) or "Delay Start" features if desired at this
point.
If you would like to delay the start time of the dishwasher
press the "DELAY" button until the desired delay time
(1-24 hrs.) shows in the Countdown Display window.
Press the "START" button to begin the cycle (Wash
Cycle Indicator Light will stop flashing)
NOTE: Rinse Agent Indicator Light will be illuminated if
the unit needs Rinse Agent.
To cancel a cycle:
Press and hold the "START/RESET" button until the
"Active" LED goes out.
Wait for about 1 minute until the dishwasher drains.
The "Clean" indicator light will illuminate when done
draining.
Turn unit off by pressing the "ON/OFF" button.
You are now ready to start a new cycle.
20
To enter the options mode (rinse agent setting, ex-
tra dry heat):
Door must be closed. Press the "ON/OFF" button to
turn the unit on.
The countdown display and one of the Wash Cycle
LEDs will be flashing.
Press and hold down the ">" button, then press and
release the "START/RESET" button. Now release the
">" button.
The "Sanitized" LED will be flashing. You are now in
the options setup mode.
Press ">" to select the option you would like to
adjust.
If the display shows "d:00" or "d:01" you can turn the Extra
Dry Heat ON or OFF.
If the display shows between "r:00" to "r:06" you can adjust
the amount of rinse agent dispensed.
To set the amount of Rinse Agent:
NOTE: If your glasses have spots on them, you need more
rinse agent. If your glasses have streaks, you need less
Rinse Agent.
Follow the prior instructions to enter "options" mode.
With the display window showing "r:00" - "r:06":
Press the "<" button to change the amount of rinse
agent dispensed.
r:00 --> Rinse Agent OFF
r:03 --> Medium amount of rinse agent dispensed
r:06 --> Highest amount of rinse agent dispensed
Press
START to save your settings.
To turn Extra Dry Heat on or off:
With the countdown display showing "d:00" or "d:01":
Press the "<" button to turn Extra Dry Heat on or off.
d:00 --> Extra Dry Heat is OFF
d:01 --> Extra Dry Heat is ON
Press
START to save your settings.