General
WARNING! Never use a machine that has
!
faulty safety equipment! If your machine
fails any checks contact your service
agent to get it repaired.
This section describes the machine´s safety equipment,
its purpose, and how checks and maintenance should be
carried out to ensure that it operates correctly.
This machine is used in combination with other products.
Please read the manual provided with the products
carefully and make sure you understand the instructions
before using the machine.
•
Connect the power unit to a grounded outlet
•
Connect the tool to be used.
Emergency stop
The emergency stop on the unit slows the connected tool
and disconnects it from the power supply.
Testing the emergency stop
•
Check that the emergency stop button is not pressed
by turning it clockwise.
•
Start the connected tool.
•
Press the emergency stop and check that the
connected tool stops.
6 – English
MACHINE´S SAFETY EQUIPMENT
Residual-current device
A residual-current device is fitted to protect operators in
case an electrical fault should occur.
Check the residual-current device
Checking of the residual-current device must be done with
the power unit connected to an earthed or grounded
power outlet.
•
Connect the power unit to an earthed or grounded
power outlet.
•
Open the cover on the residual-current device to
access the switch (1) and test button (2).
•
Set the control in the residual-current device in
position 1.
•
Press the test button. The residual-current device
must trigger to disconnect the unit from the power
supply.
•
Reset the residual-current device by first setting the
switch to 0 and then to 1.
•
Refit and tighten the cover.
The residual-current device must be tested every two
weeks with the test button.