Frost protection
The appliance is equipped with a frost
protection thermostat. This automatically
switches the compressor off in order to pre-
vent ice forming in the appliance. It starts
automatically as soon as the temperature in
the room reaches the right level for opera-
tion. The appliance can thus be used in low-
temperature environments without causing
problems. Indicator lamp
frost protection feature is activated.
General information
When used within enclosed rooms at
relative humidity levels exceeding 30%, the
dehumidifi er removes moisture from the air
and collects the water that condenses out.
This signifi cantly reduces the build-up of
condensation on walls, and prolongs the life
of furniture and electrical appliances.
A relative humidity level of between 40 and
60% is recommended to maintain a pleas-
ant room environment.
Putting the unit into
operation
The appliance is fi tted with a handle 10 and
castors 11 to make it easier to transport.
● Position the dehumidifi er on an even, fi rm
surface.
● Turn the rotary switch 1a to "off", uncoil
the power cord 12 and plug in.
● Set the desired relative humidity level
with the rotary switch 1a.
Info: The dehumidifi er only begins to
operate when the humidity in the room is
higher than the level set. The indicator lamp
is lit while the appliance is dehumidifying,
1
and goes out when the ambient humidity
reaches the value set. Should the humidity
level in the air rise, the dehumidifi er is
automatically switched on again.
is lit while the
3
Operation with water tank
or long-term use
The condensate water produced by the
dehumidifying process can either be
directed into the removable water tank 4
or via the drainage connection 8 through a
hose into an external receptacle or drain.
Operation with water tank
The water tank 4 contains an integrated
fl oat 5, which automatically switches the
appliance off when the maximum capacity
is reached.
Please ensure that the fl oat is not
obstructed, and that it contains no water.
● If the indicator lamp
the water tank 4, empty it and replace it
again.
● Indicator lamp
2
appliance will automatically restart.
Info: Indicator lamp
the tank is not properly in place.
Important: In order to prevent the
compressor malfunctioning, do not remove
and replace the water tank repeatedly in
quick succession.
Operation with drainage connection
(Fig. 13)
● Set the rotary switch 1a to "off", unplug the
appliance and remove the water tank 4.
● Open the drainage outlet 7 on the back of
the appliance.
● Firmly connect the hose supplied to
the drainage connection 8 and position
the other end of the hose over a large
collecting vessel or a drain.
● Replace the water tank 4 and restart the
appliance.
lights up, remove
2
will go out, and the
will also come on if
2
en
7