HAWA-Motronic 60-100-140
2
Product information
Intended use
Drive with integrated controls for automating wood, metal or aluminium sliding shutters.
Intended place of use
External area with a rural inland climate, no particularly high pollution burden and at least 20 km (12.4 mi) away from the sea.
Technical data
HAWA-Motronic 60, HAWA-Motronic 100 and HAWA-Motronic 140
Power supply
Max. Pre-fuse
Overvoltage category
Protection class
Operational temperature range
Degree of siuling
IP degree of protection
Max. speed
Max. drive force
Operating type
Control current (CW, CCW)
Internal resistance Control circuit
Switching point
Max. cable capacity of connecting cables
Hawa Sliding Solutions AG should be contacted if capacity exceeds 11 nF (11 nF equates to a cable length of approx. 70 m (76.5 yd),
or approx.
140 m (153 yd) if the cable is halogen-free).
Guidelines and Standards
The following directives and standards were applied to the development and construction of the HAWA-Motronic 60, HAWA-Motronic
100 and HAWA-Motronic 140.
Guidelines
2006/42/EG
2014/35/EU
2014/30/EU
Article number
Articles are identified by a 5-digit number.
General notes
The document «Safety notes» (22991) is an integral components of this planning and installation instruction.
On conclusion of the functionality check, the user should be handed the operating instructions, the document «Safety notes» (22991)
and the pamphlet «Using shading systems in snow and ice» (24102). 24102 can be downloaded from www.hawa.ch
Risk and residual risk
HAWA-Motronic 60-100-140 is EC compliant; its design and construction are in accordance with the state of the art and recognised
safety regulations. However, its use can still lead to hazards for users, property and the environment.
Disposal
Materials, accessories and packaging should be recycled in an environmentally friendly manner.
100 – 240 VAC, 50/60 Hz, 30 W
16 A
II
I
-20° C bis +60° C
1
IP 54
HAWA-Motronic 60
HAWA-Motronic 100
HAWA-Motronic 140
100 N (protected internally against
overload)
S2 - 1 min
max. 1.7 mA @ 264 VAC
> 150 k0hm
ca. 0.67 mA
11 nF
EC conformity mark
Standards
EN 61000-6-2: 2005
EN 61000-6-3: 2007 / A1: 2011
EN 60335-1: 2012
EN 60335-2-103: 2015, dynamic forces on the closing edge pursuant
to DIN EN 16005: 2013
EN 62233: 2008
10 cm/s (3 "/s)
15
---- -
16
7 cm/s (2 "/s)
3
- -
4
5 cm/s (1 "/s)
31
---- -
32
Gold contacts may be required
(Age-dependent)
9