4. MOUNTING PRECAUTIONS
Mounting height
Mount within 50mm
Ensure there are no
is 3m (9.84ft) or
from the bottom of the
moving objects in the
lower.
door engine cover.
detection zone.
3.0m
Max 50mm
(9.84ft)
If the sensor is exposed
If possible ensure no
Ensure the minimum of
to excessive rain install
accumulation of snow or
reflected sunlight from
with a Hotron weather
water on the floor.
the floor.
cover.
To maximize the effectiveness of doorway detection, install the HR100-CT outside and inside as shown below.
A
B
Side View
Plan View
A
Moving Door Leaf
B
6. MOUNTING & WIRING INFORMATION
!
WARNING
Drilling may cause electric shock.
Be careful of hidden wires inside the door engine cover.
Attach the mounting template w i th it s bo t t o m
Dril l h oles fo r mounting (3.5mm )
parallel to the same position as the bottom edge of
and wiring (10mm ) holes.
the door engine cover.
50mm
50mm
-1 Wiring to a door controller that can test the sensor.
Red
AC/DC
12 to 24 [V]
Sensor's
Black
±10%
Cable
Cable
White
N.O.
Note
EN16005
Green
COM
Yellow(+)
Collector
Set "Test input" dip switch
Blue(-)
setting Y 6 to "ON"
Emitter
Ref section 7, Dip Switch
OFF
Gray(+)
Test-P
Settings.
Y
Brown(-)
ON
Test-N
6
House connectors in the receptacle.
Replace Cover.
!
!
Disregarding this
DIN18650-1:2005
WARNING
symbol may result in
EN 12978:2003
serious injury or death.
EN 16005:2012
Special attention is required
Note
EN16005
when this symbol is shown.
12 414283-001
2. DIMENSIONS
75mm(2.95") = Standard Mounting Pitch
Accessories
Mounting Template
230mm(9.06")
Installation
3. LED INDICATORS
Instruction
Green
Standby.
Green blinking
Doorway Learning (When dip switch Y 5 is ON).
Blue
ROW 4,5 Detecting.
Cable
Red
ROW 1,2,3 Detecting.
Detection row "ROW1"("ROW2" when doorway
Orange
Base
Learning is turned ON) is detecting door movement.
Orange blinking (Fast)
Indicates a change of dip switch settings.
Mounting Screws
(2 pcs.)
Orange blinking (Slow)
Door Hold is turned Open (When dip switch Y 4 is Open) .
Green/Red blinking (Fast)
Internal Sensor Error.
Green/Red blinking (Slow)
Reflected infrared signal from the floor is very low.
5. TECHNICAL SPECIFICATIONS
Ensure no condensation
Model Name
HR100-CT
gets onto the sensor.
Detection Method
Active Infrared Reflection
Installation Height
3.0[m] (9.84 [ft]) Max
Supply Voltage
AC/DC 12 to 24 [V] ±10% 50/60Hz
AC12V-2.1 [VA] (Max)
Power Consumption
DC12V-110 [mA] (Max)
Output Holding Time
Approx. 0.5s
Response Time
0.1s
0.2s
Outer 2 Rows
1 [seconds]
Presence Timer
Use different frequency
Inner 3 Rows
2s,30s,60s or
settings for sensors in
close proximity.
Open collector: 7.5 [mA] (Max) Resistor Load
A
B
Opto coupler (NPN)
ROW 1,2
Output
Voltage: 55 [VDC] Max. Current : 50 [mA] Max.
Dark Current: 100 [nA] Max. (Resistance load)
ROW 2,3,4,5
Form A Relay DC50 [V] 0.1[A] Resistor Load
Test Input
6 [mA] Max. @ 24 [VDC]
Operating Temperature
-20 to +60 [Deg.C],(-4 to 140 Deg.F)
Operating humidity
Below 80%
IP Rate
IP54 (With Base)
Category
2 , performance level D according to EN ISO 13849-1:2008
Weight
0.55 [lb.] (0.25 [kg])
Color
Black, Silver
Cable, Mounting Screw 2pcs.,
Moving Door Leaf
Accessories
Mounting Template, Installation Instruction
Notice: Specification may be changed without prior notice.
If you need to remove the sensor body from its base
then lift the sensor body from the base and tilt it
forward to remove as illustrated.
1
1
2
-2 Wiring to a door controller that cannot test the sensor.
Red
Power
'Non Pole'
Sensor's
Black
Cable
Cable
White
R2,3,4,5
Output
Green
Note
Yellow(+)
R1,2
Set "Test input" dip switch
Output
Blue(-)
setting Y 6 to "OFF"
Ref section 7, Dip Switch
OFF
Gray(+)
Test Input
Settings.
Y
Brown(-)
ON
6
!
Depth Adjustm
CAUTION
Be careful not to inadvertently move the Depth Adjustment
ent Lever Arm
Lever Arms when replacing the cover.
7. DIP SWITCH SETTINGS
Disregarding this symbol may
CAUTION
result in injury or damage to
!
equipment.
CAUTION
Setting required to conform with
EN16005.
D = Default Setting
Function
Dip Switch X
Presence
Timer
D30s
1 2
Quantity of
R5
Detection
D
3 4
Rows
44mm
(1.73")
A
Frequency
D
5 6
Safety
N.O.
Relay
D
Output
7
Reflection
Normal
Diagnostics
D
8
Function
Dip Switch Y
Direction
OFF
Detection
D
1
AC24V-2.1 [VA] (Max)
Activation
DC24V-60 [mA] (Max)
N.O.
Relay
D
2
Output
Monitor
Normal
Mode
D
3
Door Hold
Auto
D
4
Doorway
OFF
Learn
D
5
Test Input
Setting
OFF
from Door
D
6
Controller
8.DETECTION
AREA WIDTH AND DEPTH ADJUSTMENT
Detection Area Depth Adjustment: Inner 3 Rows
Inner 3
Attach the sensor with the
rows
mounting screws provided.
adjustment
lever arm
0.5
1.5
1.0
[m]
1.5
0
[0 degree] setting
1.0
Door
2.0
2.2
Power
AC/DC
12 to 24 [V]
3.0
'Non Pole'
±10%
N.O.
R2,3,4,5
Output
1.0
[m]
0.5
1.0
COM
0
Collector
R1,2
[0 degree] setting
Output
Emitter
1.0
do not connect
do not connect
Door
2.0
2.2
3.0
!
The above illustrated detection areas represent the actual position of the infrared beams. The actual detection area observed will vary depending on the
CAUTION
sensor installation environment, object been detected and sensor settings. Please ensure that the detection area is set to conform to EN16005.
1 2 3 4 5 6 7 8
Dip Switch X
Dip Switch Y
Description
The sensor will detect a stationary object for the period of the preset
presence timer setting on the inner 3 rows.
To comply with EN16005 set the presence timer to 30s or
EN16005
more.
The number of rows of detection can be set to 5, 4, 3, 2 depending on
detection area requirements.
D
When more than two sensors are installed in close proximity to each
other select different frequency settings for each sensor to prevent
cross interference.
D
Refer to [11.Timing Chart of events] for full details on Safety Output.
D
D
A low reflected infrared signal is indicated by a slow flashing Red/Green
LED.
To ignore this low reflection error, set this dip switch to "Low
Normal
Reflection"(ON).
D
To comply with EN16005 set to "Normal".
EN16005
Description
When set to ON, pedestrians moving away from the sensor will not be
detected.
For pedestrian safety purposes when "Doorway Learn" is set
to ON the 1
and 2
row of detection will detect pedestrians
Note
st
nd
D
regardless of direction of movement.
Refer to [11.Timing Chart of events] for full details on Activation Output.
D
Set to Snow in instances where false door activations can result from
blowing snow, leaves or rubbish in the door close area.
Normal
D
!
Switch to OPEN to hold the door in the open position.
CAUTION
D
Doorway Learn allows the 1
st
row of detection to be focused
inside the door close area without detecting the door movement.
When Doorway Learn is turned ON, the sensitivity level
D
Note
of the inner row of detection is only at maximum when the
outer rows of detection are activated.
When connected to a door controller without a TEST input, set to "OFF".
When connected to a door controller with a TEST input, set to "ON"
Refer to [11.Timing Chart of events].
D
To comply with EN16005 set to "ON".
EN16005
Detection Area Width Adjustment
Area Mask
Area Mask
(Inner 3 Rows)
(Outer 2 Rows)
0.5
1.0
[m]
0
With
Base
[-8 degree] setting
1.0
Width
Door
2.0
2.2
Narrow
Wide
3.0
2.0
1.0
0
1.0
2.0
[m]
0.5
0
1.0
[-8 degree] setting
Without
1.0
2.0
Base
Door
3.0[m]
2.0
2.2
Narrow
Wide
3.0
1 2 3 4 5 6
Possible Setting Options
2s
30s
60s
D
1 2
1 2
1 2
1 2
5 Rows ON
3 Rows ON
2 Rows ON
4 Rows ON
R5
R4
R3
R2
3 4
3 4
3 4
3 4
A
B
C
D
5 6
5 6
5 6
5 6
N.O.
N.O.
Safety Output (Opto-Coupler)
N.C.
N.C.
7
Transmitter
Receiver
Transmitter
Receiver
Low Ref.
LED
8
8
IR Spot
IR Spot
Possible Setting Options
OFF
ON
1
1
N.O.
Activation Output (Mechanical Relay)
N.C.
2
Snow
3
3
Auto
Open
4
4
Door
Door
OFF
ON
5
5
With TEST
OFF
Without TEST
Without TEST
OFF
0v
ON
ON
6
0v
7
Detection Area Depth Adjustment: Outer 2 Rows
Outer 2 rows
adjustment
lever arm
3.0
2.0
1.0
[m]
2.0
1.0
[m]
0
With
[+10 degree] setting
[0 degree] setting
Base
1.0
2.0
2.2
3.0
2.0
1.0
[m]
2.0
1.0
[m]
0
[+10 degree] setting
[0 degree] setting
Without
1.0
Base
2.0
2.2
3.0
0
1.0
2.0
2.2
3.0
0
1.0
2.0
2.2
3.0