Storage; Transportation; Maintenance Of The Vibrating Pokers; Locating Malfunctions - ENAR AFE 2000 P Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.8 STORAGE

When the converter has not been used for long periods of time, it should always be stored in clean,
dry, and protected areas.

4.9 TRANSPORTATION

When transporting by vehicles, ensure the converter is safe against slipping, overturning and blows.

4.10 MAINTENANCE OF THE VIBRATING POKERS

See instruction manual of the high frequency vibrating pokers (AF_x_mu_01).
5

LOCATING MALFUNCTIONS

5.1 ELECTRIC CONVERTERS

ROBLEM
The converter is not working....................................................See if it has power
The motor works but it overheats.............................................Clean the in and out of frame air vents
The motor works slowly and it overheats................................Verify the voltage of the electrical system
FRECUENCY CONVERTERS
AFG, AFD, AFE
Clean the oil filter, clean and adjust the sparks plugs.
4.
Every 500 hours.
Clean and set the carburettor, clean the cylinders' head, set the valves.
5.
Always use original parts by every maintenance operation.
6.
The safety fittings have to be checked after every maintenance.
7.
The screed has to be sent to an authorized workshop for service every 12 months
or more frequently according to the intensity of the usage.
8.
Do not fill the petrol reservoir while smoking or near any other potential source of
danger.
Lock the petrol admission key when filling, use unleaded gas, clean the gas spelt.
9.
See the motors' manual to set the motors' speed, starting and stopping.
CAUSE/SOLUTION
Plug in need of repair
Defective switch
Converter is broken down (motor or
generator)
The connecting vibrating pokers exceed
the converters capacity.
The converter might be working at two
phases
Check the cable specifications
Check the voltage in the voltage switch (if
apply)
en
11

Publicidad