11 - 13
PEDESTRIAN
WARNING: with dip 7 to ON the input switches CLOSE: automation close as long as the
button is held down. On his release, the automation stops.
11 - 14
STOP
SENSITIVE
15 - 18
EDGE
INTERNAL
16 - 18
PHOTOCELLS
EXTERNAL
17 - 18
PHOTOCELLS
19 - 20
ELECTRIC LOCK
21 - 22
2
RADIO CH
nd
GATE OPEN
23 - 24
WARNING LIGHT
25 - 27
PHOTOCELL TX
26 - 27
AUX
28 - 29
AERIAL
5. LOGIC ADJUSTMENTS
TRIMMER
second motor delay adjustment: during closing cycle from approx. 0 to 30 sec. (on top
of the time that the card calculates automatically during the SETUP procedure); during
R. ANTA
opening from approx. 0 to 6 sec (on top of the time that the card calculates automati-
cally during the SETUP procedure).
Motor 1 torque adjustment (swing 1). The trimmer is set to provide sufficient thrust to work
FR. M1
the gate without exceeding the limits established by current standards (EN 12453). Turning
the trimmer clockwise (+) increases the motor torque, turning it anticlockwise (-) reduces it.
N.O. PEDESTRIAN button contact input – commands total opening
and closing of motor 1 – governed by dip-switches 2 and 3.
(COMMON=11);
STOP button input (normally closed contact); this stops the automatic
system. At the next command, the opposite operation to the previous
one is performed (COMMON=9). Bridge the connectors if not used;
SENSITIVE EDGE input (potential free contact N.C., dip 10 OFF) or 8,2
KΩ RESISTIVE SENSITIVE EDGE (dip 10 ON);
It works during both the opening and closing phases, causing the
temporary stop of the automation and its partial movement reversal
for 20cm, therefore freeing any obstacle (18=COMMON) Note: short-
circuit if not used.
PHOTOCELL OR SAFETY DEVICE input INSIDE the automation (Nor-
mally Closed contact); COMMON=18.
When these devices trigger during the opening phase, they tem-
porarily stop the automation until the obstacle has been removed;
during the closing phase they stop the automation and then totally
open it again. Bridge the connectors if not used.
PHOTOCELL OR SAFETY DEVICE input OUTSIDE the automation (Nor-
mally Closed contact); COMMON=18.
Then these devices trigger during the closing phase, they stop the auto-
mation and then totally open it again. Bridge the connectors if not used.
Notice: Because the control of the safety system (FOTOTEST) is per-
formed on the photocell's transmitter, this must always be pow-
ered by terminals 25 – 27, therefore if this connection is broken the
control unit will not accept any opening command. To eliminate
the safety system control, position dip-switch 6 to OFF.
ELECTRIC LOCK power output 12 Vac max. 15 W;
2nd RADIO CHANNEL output; the output mode can be selected
through Dip Switches 7 - 8;
Warning: to connect other devices to the 2nd Radio Channel
(area lighting, pumps, etc.), use an additional auxiliary relay.
GATE OPEN WARNING LIGHT output; 24 V ac, max 3W; the light
lights with the same frequency as that of the flashing light for the
entire opening and closing manoeuvre and remains on if the gate is
open and off when the gate has closed;
24 Vac external transmitting photocell power supply output for
safety device control (connect the external TX photocell only) max.
of 2 photocell transmitters;
24Vac output, 10W for the power supply of photocells, external re-
ceivers, etc.
AERIAL input (EARTH=28, SIGNAL=29);
14