Indirect application
1. Select the straight glass electrode and insert the
metal cap end into the output mouthpiece of the
handle.
2. Give the handset to the customer, making sure they
hold the glass electrode and not the handset.
3. Switch on the unit by pressing the "START/PAUSE"
button and make sure the "ENERGY" is set to the
minimum.
4. Slowly adjust the output using "ENERGY".
5. Carry out the facial massage or treatment using the
prescribed product as required. During the whole
treatment process, make sure you do not touch or
come into contact with the glass electrode being held
by the customer.
6. At the end of the treatment, lowly reduce the
"ENERGY" level to the minimum output and then
switch the "START/PAUSE" button off.
Cautions
•
The glass electrode pole will sparkle when it is still
less than one inch away from the skin with the
instrument switched on. In this case, reduce the
energy of the high frequency unit. If the customer still
feels the sparkle, they may cover their face with a
small, dry cotton towel but never with a nylon or
synthetic one.
•
Before removing the glass electrode from the skin,
decrease the "ENERGY" to its minimum setting, then
switch the power off before removing it from the skin.
•
Customers should not be allowed to wear any metal
objects or jewelry; all items must be removed prior to
beginning any treatment.
•
High-frequency treatments should not be carried
out on pregnant women, or any persons using a
pace-maker (or any electrical or rhythmic
heart-regulating device).
•
The products used with the high-frequency
treatment must not contain any alcohol or spirit-based
substances in order to prevent accidental combustion
from arcing.
•
Never touch the inner eye (eyeball) area with any
high-frequency electrode.
•
Only hold the handle of the high-frequency handset.