Descargar Imprimir esta página

Wiring Diagram - Velleman PIR1200B Manual Del Usuario

Detector de movimientos pir
Ocultar thumbs Ver también para PIR1200B:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 13
4.
Connect the wires according to the illustration 3 on page 2.
1
recess
2
recess
5.
Attach the sensor to the bottom part of the housing. Screw the
housing shut and connect the device with the mains.

5. Wiring Diagram

Refer to illustration 4 on page 3 of this manual.
1
brown
2
blue
3
red
4
input
6. Test
Turn the LUX adjustment anticlockwise until the max. position is
reached and turn the TIME adjustment anticlockwise until the min.
position is reached.
It takes the device some 5 to 10 s to react when movement is detected.
The lamp will light for 5 to 15 s.
7. Notes
A qualified electrician should install this device.
Do not block the front of the detection window and make sure the
detection area holds no moving objects.
Do not install the device close to air conditioning vents, radiators, etc.
Do not open the housing and attempt to repair the device yourself in
case of malfunction. Only skilled technicians should repair this device.
8. Troubleshooting
The lamp does not work.
Check the power supply and the lamp.
o
Sensitivity is poor.
An object may be blocking the detection window.
o
Check the ambient temperature.
o
Please check if the signal source is located within the boundaries of
o
the detection range.
Check the installation height.
o
Check if the moving orientation is right.
o
V. 03 – 14/03/2017
PIR1200B/PIR1200W
3
red
4
blue
5
5
6
5
output
6
lamp
7
sensor
brown
input
©Velleman nv

Publicidad

loading

Este manual también es adecuado para:

Pir1200w