Message on the
Fault code
display
C1F0521
E-track motor
C1F0513
E-track motor
1247 - 001 - 09.07.2019
DTC description
Output current over-
load
Circuit open
Indication on the ma-
chine
Cutting can continue
but E-track can not be
used for drift compen-
sation until fault is re-
solved.
Possible action
Check if E-track is stuck or
jammed, and if so, resolve the
problem and reset fault codes.
Try E-track again after 1 mi-
nute. If fault code still exists
check contact your service
agent for further information.
Check connection between
Etrack harness to Cowling har-
ness. Check connection be-
tween Etrack actuator and E-
track harness. Check damage
to E-track and harness. If
found repair and reset fault co-
des.
If problem still exists, contact
your service agent for further
information.