Comet K Steel S Manual De Instrucciones página 35

Ocultar thumbs Ver también para K Steel S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
PROBLEMS
No water comes out of the
nozzle or flow rate is poor.
Water leaking from under
the high pressure cleaner (S,
1001-1251-1501 without Total
Stop, Xtreme).
Water leaking from under
the high pressure cleaner
(Xtreme).
The high pressure cleaner
stops during operation.
Having released the spray
gun lever (22) and after about
13 seconds, the Total Stop
function fails to activate
(TS, Eco).
The high pressure cleaner
starts again spontaneously
from the Total Stop condition
(TS, Eco, 1001-1251-1501 with
Total Stop).
When the master switch (1)
is turned notwithstanding the
push button (21) has been
pressed (1001-1251-1501
with Total Stop, Xtreme), the
motor hums but does not
start.
CAUSES
No water.
Priming too deep.
Water nozzle clogged.
Pump priming is incomplete.
Back-flow preventer fault.
Thermostatic valve triggered.
Relief valve triggered.
Tripping of system cutout
device to which the high
pressure cleaner is connected
(fuse, RCCB, etc.).
Tripping of thermal protection
or ampere cut-out protection.
W o r k p r e s s u r e b e l o w
30  bar/435  psi: the device
does not activate under such
conditions.
Remember not to leave
the high pressure cleaner
in by-pass for more than 3
minutes.
Leaking and/or dripping in the
delivery circuit.
E l e c t r i c a l s ys te m a n d / o r
extension and/or power cable
(Xtreme) are inadequate.
REMEDIES
Check that the mains water tap is fully open
or the suction pipe can prime.
Check that the priming depth conforms to
what is specified in the "Specifications and
technical data" paragraph.
Clean and/or replace the nozzle as explained
in the "Routine Maintenance" paragraph.
Follow the instructions given in the
"Operation – Preliminary activities"
paragraph.
Refer to the relative manual.
Reduce the time the high pressure cleaner
stays in the by-pass operating mode (see
also the "Stopping operation" paragraph).
IF THIS HAPPENS PERSISTENTLY DO NOT
USE THE HIGH PRESSURE CLEANER AND
CONTACT A SPECIALIZED TECHNICIAN.
Reset the cutout device.
IN cASE THIS TRIPS AGAIN, DO NOT USE
THE HIGH PRESSURE CLEANER AND
CONTACT A SPECIALIZED TECHNICIAN.
Follow the instructions of the "Safety
devices" paragraph.
None.
Check soundness of the delivery circuit.
Make sure the power line connection
instructions have been followed (see the
Instruction manual – Safety precautions),
a n d c h e c k t h e i n s t r u c t i o n s i n t h e
"Installation" paragraph.
EN
35

Publicidad

Tabla de contenido
loading

Tabla de contenido