5.- Pull the spray gun trigger, holding it until the
sprayed product is clean thinner and free from the
product previously applied.
It is considered that the unit and its accessories are
totally clean when the product sprayed through the
gun, and that circulating through the product return
probe No. 2, is clean thinner and free from the
product previously applied, meaning that the
process must be repeated as many times as
necessary.
Once the unit and its accessories are clean, and as
a prior step before definitively stopping it, the
Depressurisation procedure described before in
Section 10 of the Manual must be applied.
Clean the Suction Probe filters and those of the spray gun.
Remove any remains of product from the gun, hoses and
the rest of the unit with a cloth soaked in thinner.
Keep gasket areas free of accretions and foreign bodies.
The air cap is a precision component. Any deformation,
especially in the product outlet orifices, may cause
malfunctions in its operation and incorrect or deficient quality
spraying.
Before starting to work, verify the state of the product hoses and
the connections of the elements through which the product flows.
In order to carry out maintenance or repairs, first disconnect the
unit from the compressed air distribution network.
Never move the unit by tugging on the hoses.
Always place the unit at a distance of least 6 metres away from
where the product is to be applied.
Do not apply excessive force or inadequate tools for maintaining
and cleaning the unit. Some repairs must be done with special
page 9
If necessary, dip the air cap in thinner in order to soften the
remains of product or dirt. Once softened, blow the cap with
compressed air until any remains of product and thinner are
eliminated.
For automatic cleaning of the gun, tools and accessories
used in the mixing and preparation of the product to be
applied, we recommend the use of SAGOLA Washing
Machines.
IMPORTANT
The gun can be cleaned with thinners or detergents in
a gun washing machine.
If you opt for this cleaning system, we advise you to
remember the following considerations, which, if not applied,
may damage the gun and render the warranty null and void.
- Do not submerge the gun in solvent or detergents longer
than the time required for cleaning.
- Do not use the gun immediately after cleaning has been
completed.
- Ensure that there is no thinner or detergent inside and that
it is completely free of these. Other cleaning systems can
be used (ultrasound).
14. MAINTENANCE
tools on some occasions. In these cases, you must contact the
Customer Service of SAGOLA. Any handling of this product by
non-authorised personnel would render the warranty null and
void.
The unit must be overhauled on a periodic basis to check the
status of its components and replace these when they are not
in perfect condition.
IN ORDER TO OBTAIN THE BEST POSSIBLE RESULTS,
ALWAYS USE ORIGINAL SAGOLA SPARES THAT
GUARANTEE TOTAL INTERCHANGEABILITY, SAFETY AND
PERFECT OPERATION.
15. PARTS LIST