When the battery is low, the battery status bar border will turn red
and flash to alert the operator. The time remaining will typically be
10 minutes.
Note: It is recommended that before each BA team enters the fire, the camera
should be used with a fully charged rechargeable battery.
Disposal of batteries should be in line with local procedures and they should
be segregated from domestic waste. Alternatively, the batteries may be
returned to e2v technologies for safe disposal.
The battery pack will self-discharge at approximately 2% per day. Battery
packs that have been stored off-charge for two weeks will run a camera for
at least two hours. It is recommended that the rechargeable batteries are
placed into storage fully charged and are routinely recharged so as to be
ready for use and to maintain performance. Shelf life is maximised by
storage between 10 °C and 25 °C (50 °F and 77 °F).
To maintain the accuracy of the battery charge indicator, e2v recommends
that batteries be occasionally fully discharged in a camera before charging.
3.2

Battery Charger

Warnings
The charger has been designed for indoor use only and should not be exposed
to water or dust. Do not cover the charger while in use.
The charger is turned on once connected to the mains. Disconnecting it from the
mains will turn it off. The mains socket should be accessible to allow
disconnection if a fault should occur.
The charger is supplied with several mains cables for worldwide use; ensure
that the correct mains lead is used. Check the condition of the mains lead before
use.
Hazards
The charger contains dangerous voltages and the cover should not be removed.
There are no user-serviceable parts inside the charger or charging shoe.
Cautions
Do not charge batteries with too high or low battery temperatures.
Only use the Argus
(P7030CS) with this charger.
Ensure that the battery charger output lead has been correctly fitted to the
charging shoe before connection to the mains.
Connect the charging shoe to the charger, plug into the mains and turn the power
on. The LED on the charger will be orange for 5 – 7 seconds and then turn yellow.
Insert the battery pack into the charging shoe. The LED will remain yellow while the
charger is in start up trickle mode. Once the fast charge mode starts, the LED will
turn orange.
© e2v technologies (uk) limited
TM
4 Rechargeable Battery (P7030R) and Charging Shoe
104077
DAS709758AA (UK) version 7, page 15