1. Do not involve a conductor with a voltage higher 1000V DC or 750V AC
RMS.
2. Any incorrect operation may result in serious and/or fatal injury.
3. Extremely careful when working next to non insulated conductor or bus
bar. The accidentally contact with the conductor may result in dangerous
electric shock. Some protection equipments like rubber sole footwears,
protection gloves or any other insulated material must be user to keep
you body insulated from the earth to warrant a safety operation.
4. Do not try to open the equipment or do a repair during a measurement.
• Jaw Opening: 57mm conductor, bus bar 70 x 18mm.
• Operation environment: 0°C to 50°C, RH < 70%.
• Storage environment: -20°C to 60°C, RH < 80%.
• Temperature coefficient: 0.1 x (specified accuracy) / °C (< 18°C or >
28°C).
• Altitude: 2000m.
• Output: Spiral cable with banana connector.
• Dimensions: 264(H) x 100(W) x 44(P)mm.
• Weight: Approx. 400g.
ELECTRICAL SPECIFICATIONS (23°C±5°C, 70% RH maximum)
• Range: 0 ~ 1000A AC maximum
• Output: 0 ~ 1V RMS with a input impedance > 1MΩ
• Transform relation: 1mV / A
• Accuracy System: Jaw Accuracy + DMM Accuracy
Jaw:
• Overload protection: 1200A for 60 seconds maximum

OPERATOR SAFETY

GENERAL SPECIFICATIONS

0 ~ 400A ± (1.5% + 2A) to 50Hz ~ 60Hz
0 ~ 400A ± (3.0% + 2A) to 61Hz ~ 400Hz
400A ~ 1000A ± (2.0% + 3A) to 50Hz ~ 60Hz
400A ~ 1000A ± (3.5% + 3A) to 61Hz ~ 400Hz