EN 60950-1:2006+A11:2009 - "Safety of Information Technology Equipment."
A "Declaration of Conformity" in accordance with the preceding directives and standards has been
made and is on file at our EU representative TDK-Lambda Limited, located at Kingsley Avenue,
Ilfracombe, Devon EX34 8ES, UK.
WARNING: This is a Class A product. on a domestic environment this product may cause radio
interference in which case user may be required to take adequate measures.
SAFETY APPROVALS: UL 60950-1:2007 Second Edition, UL Listed, C-UL for Canada,
IEC 60950-1:2005 Second Edition, CE marking, when applied to the GEN3300W/5000W product,
indicates compliance with the Low Voltage Directive 2006/95/EC in that it complies with
EN 60950-1:2006/A11:2009 Second Edition.
SAFETY INSTRUCTIONS
CAUTION
The following safety precaution must be observed during all phases of operation, service
and repair of this equipment. Failure to comply with the safety precautions or warnings in
this document violates safety standards of design, manufacture and intended use of this
equipment and may impair the built-in protections within.
Nemic-Lambda shall not be liable for user's failure to comply with these requirements.
INSTALLATION CATEGORY
The Genesys power supply series has been evaluated to INSTALLATION CATEGORY II.
Installation category (over voltage category) II: local level, appliances, portable equipment
etc. With smaller transient over voltage than Installation Category (over voltage category)
III.
GROUNDING
This product is a Safety Class 1 instrument. To minimize shock hazard, the instrument
chassis must be connected to an electrical ground. The instrument must be connected to
the AC power supply mains through a three conductor power cable, with the ground wire
firmly connected to an electrical ground (safety ground) at the power outlet.
For instruments designed to be hard-wired to the supply mains, the protective earth terminal
must be connected to the safety electrical ground before another connection is made. Any
interruption of the protective ground conductor, or disconnection of the protective earth
terminal will cause a potential shock hazard that might cause personal injury.
WARNING
OUTPUT TERMINAL GROUNDING
There is a potential shock hazard at the RS232/485 and the IEEE ports when using power
supplies with rated or combined voltage greater than 400V and the Positive Output of the
Power Supply is grounded.
Do Not connect the Positive Output to ground when using the RS232/485 or IEEE.
FUSES
Fuses must be changed by authorized Nemic-Lambda service personnel only. For
continued protection against risk of fire, replace only with the same type and rating of fuse.
Refer to maintenance instructions in chapter 9 for fuses rating.
INPUT RATINGS
Do not use AC supply which exceeds the input voltage and frequency rating of this
instrument. The input voltage and frequency rating of the power supply
Genesys 3300W/5000W series .