3
Installation, Cleaning and Maintenance
3.1 General Notes
Technical maintenance, installation and other actions should be carried out by authorised specialised technicians only, using original spare
parts. Failure to meet these conditions may result in the loss of warranty.
3.2 Installation
The equipment installation should carried out in accordance with building regulations, rules and best practice for accident prevention,
fire prevention standards and existing European standards.
3.2.1
Preparation
Remove the PVC protective film; do not use sharp tools to avoid scratching. Clean the inside and outside of the equipment using protective
gloves.
3.2.2
Placement
Select a location where the equipment can be installed away from possible sources of heat (like ovens or stoves) and away from
direct sunlight. Ensure good air circulation around the equipment, maintaining the distance between the wall and the back of the
equipment. Never obstruct the front grid: the lack of ventilation seriously affects the operation and can lead to severe damage to the
equipment.
3.2.3
Leveling
The equipment must be installed on a flat and sturdy surface, to ensure a 4-point support stability. The height adjustable telescopic legs should
be adjusted for a precise leveling.
3.2.4
Water drain (except Y2-3 model)
This equipment is fitted with a drain outlet for cleaning.
In case you do not opt for a connection to the sewer, use the recovery tray of condensation water placing it from the front on the
sliders under the equipment.
The drainage of condensation water can be compromised if the equipment is not leveled.
3.2.5
Electrical connection
The unit is supplied with a plug in accordance with current standards of practice and with an power cord whose length is sufficient to allow
connection to the mains.
Models
Section (nominal)
Manufacturer code with CEE 7/7 standard plug:
Manufacturer code with BS 1363 optional plug:
The mains should be easily accessible and sized for the maximum consumption (see rating plate), and should have an EARTH CABLE.
For direct connections to the network, you should always install an interrupting device (circuit breaker) in accordance with
international standards. Never use sockets or plugs without earth cable, nor use adapters or extension cords.
3.2.6
Replacement of power cord
If the power cord is damaged, this must be immediately replaced by an original one supplied by the manufacturer or by the technical services.
3.3 Cleaning
To ensure correct hygiene and conservation, clean the equipment regularly as indicated:
Switch off the appliance and unplug it, or switch off the circuit breaker.
Clean the surfaces using a dampened cloth with a mild detergent water solution; then rinse with a dampened cloth with clean water
and finally wipe with a dry cloth.
Do not use cleaning products containing acids or chlorine (such as bleach), or abrasive materials (such as pads) or pressurized water
(such as hoses).
3.4 Maintenance
To ensure that the equipment lasts for a long time and functions correctly, please follow these precautions:
3.4.1
Condenser
Regular maintenance of the condenser should be carried out as follows:
Switch off the appliance and unplug it or switch off the circuit breaker.
Unscrew the front air vents; be careful with cable holder, do not stretch the cables.
Carefully vacuum (preferably) or brush the condenser blades.
Finally, screw back the front air vents.
MNS00054.00
TEC
Instruction Manual
H05VV-F Power Cord
Y2-3, Y2-5 e Y2-7 (monophasic)
2
3 x 1.0 mm
43001004
43001001
N.ºMNS00054.00
Y2-10 e Y2-14 (three-phase)
2
5 x 2.5 mm
12/50