12.1
USER INTERFACE
DISPLAY MINIMUM TEMPERATURE
•
Press and release the button.
•
The message "Lo" will be displayed, followed by the minimum temperature reached.
•
Press the button or wait 5 seconds to display the normal temperature.
DISPLAY MAXIMUM TEMPERATURE
•
Press and release the button.
•
The message "Hi" will be displayed, followed by the maximum temperature reached.
•
Press the button or wait 5 seconds to display the normal temperature.
VIEWING AND EDITING SET POINT
•
Press and release the button SET: the set point will be immediately displayed.
•
The Leds
•
To modify the value use the buttons
•
To save the new set point, press the SET key or wait 15 seconds to exit the
programming function.
CANCELLATION STORED TEMPERATURES
•
To cancel the stored temperatures, to display the maximum or minimum temperature
use the buttons
•
Press the SET button until the "rST" message flashes 3 times.
428000925100
and
start to flash.
and
.
SUPERCAPRI
72
and
.
EN