Operating instructions
The RDJ100RF/SET consists of a RDJ100RF wireless temperature controller and a RCR100/433 receiver. The RDJ100RF
allows you to set the desired room temperature (setpoint) for the desired time. The unit features an ergonomic setting knob for
easy temperature control.
Actual room temperature in ºC
The unit controls to the selected
comfort temperature
The unit controls to the selected
energy saving temperature
The unit controls to the frost
protection temperature at 5 ºC
Indicates when the temperature
setpoint was changed by the user.
This setpoint will be maintained until
the next switching time. This function
is only active in automatic mode and
comfort mode
Setting knob
Warmer / colder for selecting
the temperature
Battery compartment
2 alkaline batteries type AA, 1.5 V
Operating mode selector
This silder determines how the thermostat
operates
Automatic mode: In this position the thermostat switches at
the programmed times and temperatures
In this position the thermostat ignores all programmed times
and runs permanently at the temperature set in
In this position the thermostat ignores all programmed times
and runs permanently at the temperature set in
Frost protection Thermostat runs permanently at 5°c
Advance button
Switches the operating mode from comfort to energy saving,
or vice versa, until the next switching time in automatic mode
A6V101035990_en--_a / 2017-1-1
RDJ100RF/SET
Display
Indicates when heating is
demanded
Replace batteries
Frost protection: The unit controls
continuously to the frost protection
temperature at 5
Energy saving mode: The unit
controls continuously to the energy
saving temperature
Comfort mode: The unit controls
continuously to comfort temperature
Automatic mode: The unit controls
to the selected time and
temperature programs.
Programming selector
Time setting position
A1
First switch on time
A2
First switch off time
A3
Second switch on time
A4
Second switch off time
Comfort (ON) temperature setting
Energy saving (OFF) temperature
setting
Set the controller to RUN after
RUN
programming is completed
Subject to alteration
Introduction
This leaflet provides you easy-to-follow instructions to set-
up your RDJ100RF programmable room thermostat.
Contents
Commissioning
Initial power up
How do I set the Clock
How do I set the ON and OFF times
How do I set the comfort (ON) temperature
How do I set the energy saving (OFF) temperature
How do I Change batteries
Configuration instructions for the Siemens RCR100RF/SET
(Wireless RF version only)
Energy savings tips
°
C
Commission
·
Remove the black transit tabs from the
alkaline batteries.
·
Check to see if the battery compartment is
in the correct position.
·
If no batteries are inserted, fit 2 alkaline
batteries type AA in the battery
compartment.
Initial power-up
Once batteries are inserted, all symbols are
displayed as shown for around 2 seconds.
Set clock
1. Move the programming selector to
position
2. The current time setting flashes.
3. Turn the setting knob counterclockwise -
to decrease the time, or clockwise +
to increase the time.
4. When the correct time is displayed move
the programming selector to any
other position to confirm your setting.
Set the first switch-on time (first
comfort time)
1.
Set the programming selector to
position A1. The setting for the first
switch on time flashes.
2.
Turn the setting knob counter clockwise
- to decrease the time, or clockwise +
to increase the time.
3.
When the required switch on time is
displayed, move the programming
selector to any other position to confirm
the setting.
Siemens Building Technologies / HVAC Products
DE
EN
FR
IT
NL
ES
PT
CS
HU
PL
FI
ZH
TR
EL
RO
DA