INTENDED USE

The IR Thermometer measures surface temperatures by measuring the
amount of infrared emitted off the object. This type of measurement
is a non-contact measurement of the surfaces temperature. This tool
comes fully assembled. This tool has been designed with features that
allow for quick and easy set-up.
Belt Hook (Fig. 2)
(Optional Accessory)
WARNING: To reduce the risk of serious personal injury, DO
NOT suspend tool overhead or suspend objects from the belt hook.
ONLY hang tool's belt hook from a work belt.
WARNING: To reduce the risk of serious personal injury,
ensure the screw (P) holding the belt hook is secure.
IMPORTANT: When attaching or removing the belt hook, use only the
screw (P) that is provided.
The belt hook (O) can be attached to either side of the tool using only
the screw (P) provided, to accommodate left- or right- handed users.
If the hook is not desired at all, it can be removed from the tool.
To move belt hook, remove the screw (P) that holds the belt hook in
place then reassemble on the opposite side.
OPERATION
WARNING: To reduce the risk of serious personal injury,
turn tool off and disconnect battery pack before making any
adjustments or removing/installing attachments or accessories.
Installing and Removing the Battery Pack
(Fig. 4)
NOTE: Make sure your battery pack is fully charged.
To install the battery pack (C) into the tool handle, align the battery with
the rails inside the tool's handle and slide it firmly into the handle until
you hear the lock snap into place.
FIG. 4
To remove the battery pack from the tool, press the release button (B)
and firmly pull the battery pack out of the tool handle. Insert it into the
charger as described in the charger section of this manual.
Select Operating Mode
Read the following steps before operating the IR thermometer.
CHOOSE UNITS OF MEASUREMENT
Turn the unit on by engaging the trigger. Once the screen comes on
push the C/F button until the units of measurement is on the correct
setting for the application.
CHOOSE EMISSIVITY
Turn the unit on by engaging the trigger, once the screen comes on
push the EMS button for emissivity adjustment. When then EMS is
flashing on the screen, use the up or down arrow buttons to choose
the emissivity. Please refer to the chart in order to choose the correct
emissivity. Remember, emissivity is adjustable by 0.01.