General Power Tool Safety Warnings; Work Area Safety; Electrical Safety - Parkside PBH 800 A1 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54
Total vibration value:
Total vibration values (vector total of three direc-
tions) determined in accordance with EN 60745:
Hammer drilling
in concrete: a
= 6.5 m/s
h(HD)
Chiselling: a
= 7.438 m/s
h(CHeq)
NOTE
The vibration level specified in these instruc-
tions has been measured in accordance with
a standardised measuring procedure and
can be used for equipment comparisons. The
specified vibration emission value can also
be used to make an initial exposure estimate.
WARNING!
The vibration level varies depending on the
use of the power tool and may be higher
than the value specified in these instructions
in some cases.
Regular use of the power tool in this way may
cause the user to underestimate the vibration.
Try to keep the vibration loads as low as
possible. Measures to reduce the vibration
load are, e.g. wearing gloves and limiting the
working time. Wherein all states of operation
must be included (e.g. times when the power
tool is switched off and times where the
power tool is switched on but running without
load).
PBH 800 A1
2
, K = 1.5 m/s
2
2
, K = 1.5 m/s
2
General Power Tool
Safety Warnings
WARNING!
Read all safety warnings and all instruc-
tions. Failure to follow the warnings and
instructions may result in electric shock, fire
and/or serious injury.
Save all warnings and instructions for future
reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-
operated (cordless) power tool.

1. Work area safety

a) Keep work area clean and well lit.
Cluttered or dark areas invite accidents.
b) Do not operate power tools in explosive atmo-
spheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks
which may ignite the dust or fumes.
c) Keep children and bystanders away while
operating a power tool. Distractions can cause
you to lose control.

2. Electrical safety

a) The mains plug of the power tool must fit into
the socket. Never modify the plug in any way.
Do not use any adapter plugs with earthed
(grounded) power tools. Unmodified plugs
and matching outlets will reduce risk of electric
shock.
b) Avoid body contact with earthed or grounded
surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of elec-
tric shock if your body is earthed or grounded.
GB │ IE
13■

Publicidad

Tabla de contenido
loading

Tabla de contenido