Tool change
Turning the reversing plates
3
SKF 25
WARNING
Risk of injury!
►
Do not use damaged, soiled or worn tools.
►
Change tools only when the machine is switched off and at a
standstill. Pull the plug out of the mains socket.
►
Only use tools, adapter and accessories that match the
machine.
1
Place the machine onto the upper side (power connecting
cable ).
Remove the screw (2).
Remove the housing (1).
Remove the fixing screw (3), turn the reversing plate and
tighten the fixing screw again.
Repeat the procedure for all reversing plates of the miller.
Replace the housing again and tighten the screw (2).