Risk of electric shock caused by
the XCI box falling down off the wall
and into water.
If it is not secured properly and cor-
rectly, the XCI box can fall down off
the wall, causing an electric shock.
If an XCI box falls down off the wall,
it must be taken out of service imme-
diately. Replace the XCI box with a
new one or have it checked by the
Miele Customer Service Department.
Carrying out the installation
Service and repair work must only be
carried out by a suitably qualified elec-
trician in accordance with all appropri-
ate local and national safety regula-
tions.
Disconnect the Miele Professional
machine from the mains voltage.
Attach the XCI box to the wall using
the 4 screws (4 x 40) and plugs (S6)
provided. See Fig. in the
"" chapter.
Alternatively, the XCI box can be at-
tached to the wall using the adhesive
strips provided. See Fig. in the
"" chapter.
Establish the connection between the
XCI box and the Miele Professional
machine and the external hardware
(e.g. payment system).
When connecting external hardware
provided by other manufacturers, the
cable cross-section must not be less
2
than 1.0 mm
with a maximum cable
length of 2.50 m (98 ¹/₃").
Mounting the cable strain relief
The connection cables of external hard-
ware must be fastened to the XCI box
using cable glands and cable strain re-
lief fixtures. See Fig. in the
"" chapter at the end of these operat-
ing and installation instructions.
Remove the lid from the XCI box (re-
move the 2 screws).
Remove one or more of the cable
strain relief fixtures a.
Stand the XCI box on its narrow end
so that the sealed connection holes
are at the top.
Using a screwdriver, press out the
round indentation in the connection
hole b.
Tip: Pierce through the groove round
the edge at several places using a
screwdriver.
Insert the counter nut c.
Screw on the threaded fitting d.
Tip: Slide the screw cap e over the
end of the connection cable for the ex-
ternal hardware.
Guide the connection cable through
the threaded fitting and into the
XCI box.
Tighten the screw cap.
The screw cap provides protection
against moisture and dust.
Secure the connection cable with the
strain relief f.
Make the required connections for
the external hardware in the XCI box.
Close the lid on the XCI box (screw in
the 2 screws).
en - English